EN
Technical data
20
751.792 | Z01 | 1504
Detailed battery charging
data
12 V system
24 V system
Permissible battery voltage
range
9-17 V
17.1-34 V
Deep discharge pre-warning at 12.0 V
24 V
Deep discharge protection at
11.7 V
23.4 V
Switch-on voltage
12.5 V
25 V
Cut-off voltage for float
charge (Float)
14.1 V
28.2 V
Cut-off voltage/activation for
maintenance charge (Boost)
14.4 V /
≤
12.7 V
28.8 V /
≤
25.4 V
Cut-off voltage/activation for
equalise charge (Equal)
(only with the liquid battery
type setting)
15.0 V /
≤
12.2 V
30.0 V /
≤
24.4 V
Load circuit
Output voltage
(same as battery I)
12 V DC or 24 V DC
Maximum output current
20 A
Connections
Terminals
for batteries, solar module and
load circuit
USB charge socket
5 V, 1500 mA
Other connections
StecaLink bus system (RJ 45)
Display
LEDs
4 (multicolour)
Содержание Solarix 2020-x2