EN
Installation
8
751.792 | Z01 | 1504
Mount the solar charge controller upright on a non-
inflammable surface.
Maintain a minimum clearance of 10 cm above and below
the unit to ensure free circulation of air.
Mount the solar charge controller as close as possible to the
batteries (but with a safety clearance of at least 30 cm).
Step 1 Mounting the solar charge controller
1.
Use the drilling template to mark the hole positions on the
wall.
2.
Drill 4 holes (Ø depending
on the wall material and
the fasteners used).
3.
Use 4 suitable screws (not
provided) to fasten the con-
troller to the wall. The cable
openings must face down-
wards.
Step 2 Connecting the solar charge controller
Danger of fire and explosion
Solar modules generate electricity under incident light.
The full voltage is present, even when the incident light
levels are low. You must therefore protect the solar
modules from incident light during installation, e.g.
cover them.
Do not touch exposed cable ends.
Take care to ensure that the cables do not touch each
other.
Use only insulated tools.
Ensure that all loads to be connected are switched off.
Connections must always be made in the sequence
described below.
Ø approx. 5 mm