EN
Maintenance
12
751.792 | Z01 | 1504
5
Maintenance
Clean the solar charge controller as necessary using a brush
or soft cloth. Do not use water for cleaning.
Ensure adequate ventilation at the rear side of the housing
(heatsinks).
Check the cable strain relief.
Check that all cable connections are secure. Tighten screws if
necessary.
Check all terminals for signs of corrosion.
All components of the photovoltaic system must be checked
at least annually, according to the specifications of the
respective manufacturers.
6
Self test
A self test of the solar charge controller can be executed if
required. An adjustable, stabilised power supply unit with
current limiting is required for the self test.
1.
Disconnect all connections to the solar charge controller and
wait for at least 1 minute.
2.
Adjust the power supply to a voltage of 7.25 V (± 0.25 V)
and set the current limit to max. 2 A (0.5 A to 2 A).
3.
Connect the power supply unit with the correct polarity to
the solar module terminals.
The self test starts automatically. The results are displayed
according to the following table:
Display
Meaning
LEDs 1 to 4 flash green
Self test passed, no device faults
LEDs 1 to 4 flash red
Internal power supply fault or tem-
perature sensor fault
LED 1 flashes red
Fault in auxiliary battery charge
control
Содержание Solarix 2020-x2