Faults and remedies
EN
751.792 | Z01 | 1504
17
Error/
Fault message
Cause
Remedy
Solar module
LED 2 lights up
blue
Solar module
connected with
incorrect polarity
Connect the solar mod-
ule with the correct
polarity
LED 2 lights up
red
Short circuit at
solar module
input
Correct the cause of the
short circuit
LED 2 flashes
red (slowly)
Solar module
overcurrent
-
Disconnect the solar
module
-
Correct the cause of
the overcurrent
-
Reconnect the solar
module
LED 2 flashes
red (fast)
Shutdown due to
overcurrent
-
Disconnect the solar
module
-
Correct the cause of
the overcurrent
-
Reconnect the solar
module
LED 2 flashes
red/green
Solar module
overvoltage
-
Disconnect the solar
module
-
Correct the cause of
the overvoltage
-
Reconnect the solar
module
Содержание Solarix 2020-x2
Страница 23: ...DE...