Installation
EN
751.792 | Z01 | 1504
9
Cable cross sections
Distance
3 m
5 m
10 m
Current
20 A
4 mm²
6 mm²
10 mm²
10 A
2.5 mm²
4 mm²
6 mm²
5 A
2.5 mm²
2.5 mm²
4 mm²
The specified cable cross sections are minimum values. Please choose
somewhat higher cross sections (max. 10mm²) for a higher efficiency.
Cable terminal tighten-
ing torque
1.2 Nm
Cable lengths
Max of 10 m for solar module connection
cable
Max of 2 m for battery connection cable
Max of 10 m for load connection cable
Reference potential
Common negative pole (negative pole connect-
ed to common ground), earthing is not re-
quired
Fuse
30/40 A
Load output
240 W
max
(12 V)
480 W
max
(24 V)
U
max
=60 V
I
max
=20 V
Fuse
30/40 A
max. 2 m
2.5-10 mm²
max. 10 m
2.5-10 mm²
max. 2 m
2.5-10 mm²
2.5-10 mm²
max. 10 m
Содержание Solarix 2020-x2