Fig. 4: Example 2 of an HTML page
To display the HTML pages, the chart.js licence-
free software is used, www.chartjs.org. Copy-
right (c) 2013-2015 Nick Downie."
The HTML pages are the simplest way to update the firmware of the
inverter. The corresponding page is shown below.
Fig. 5: View of the firmware update
3.6.3 RS485 bus
The inverter communicates with other devices via an RS485 bus. The
following applies: The following applies:
n
The inverter has two RS485 interfaces (RJ45 sockets) on the
lower side of the casing.
n
The beginning and end of the RS485 bus must be terminated;
see 3.6.5, p.25.
n
Standard RJ45 cables can be used as bus cables (Cat-5 patch
cables, not supplied). Use an alternative data connection cable
for longer connections; see 3.6.4, p.24 .
n
The inverters connected to the RS485 bus operate as slaves.
EN
750.661 | Z03 | 2016-09-12
23