9.8.2 Advance Transducers
Not all systems use advance transducers. If yours doesn’t, skip ahead to the next section.
There are two advance transducers per track, each having two wires: one black wire and one
white wire. At a single-track site, the wires should be labeled
ADV1
and
ADV2
. At a double-
track site, they should be labeled
ADV1-TRACK1
,
ADV2-TRACK1
,
ADV1-TRACK2
, or
ADV2-TRACK2
, whichever is appropriate. At double-track sites, the wires from the advance
transducers on track1 connect to the leftmost SmartScanNG² detector. The wires from track2
connect to the rightmost SmartScanNG² detector.
9.8.3 Dragging-Equipment Detector
Most, but not all, systems use dragging-equipment detectors. If your site doesn't use them,
skip ahead to the next section.
When used, there is one dragging-equipment detector per track, each having two wires —
usually, one black wire and one white wire. The color of your wires may be different.
At double-track sites, the wires from the dragging-equipment detector on track1 connect to the
leftmost SmartScanNG² detector. The wires from track2 connect to the rightmost
SmartScanNG² detector.
Refer to the wiring chart in
Section 9.8
.
9.8.4 High-Load/High-Wide Detector
Some systems use high-load detectors. Others use high-wide detectors. If your site doesn't
use either of them, skip the instructions below and go to the next section.
When used, there is one high-load/high-wide detector per track, each having two wires.
At double-track sites, the wires from the high-load/high-wide detector on track1 connect inside
the leftmost SmartScanNG² detector. The wires from track2 connect inside the rightmost
SmartScanNG² detector.
Refer to the wiring chart in
Section 9.8
.
To designate High-Load alarms
, YES must appear after the words High Load on the
Equipment menu, and Separate must appear after the words Clearance Mode on the
Equipment menu.
To designate High-Wide alarms
, YES must appear after the words High
Load on the Equipment menu, and Multiplexed must appear after the words Clearance Mode
on the Equipment menu.
Содержание Smartscan NG2
Страница 6: ...6 14 May 2021 SmartScanNG User s Guide for Wayside Enclosure Components EUD 2018086 00 Rev 3...
Страница 10: ...10 14 May 2021 SmartScanNG User s Guide for Wayside Enclosure Components EUD 2018086 00 Rev 3...
Страница 42: ...42 14 May 2021 SmartScanNG User s Guide for Wayside Enclosure Components EUD 2018086 00 Rev 3...
Страница 48: ...48 14 May 2021 SmartScanNG User s Guide for Wayside Enclosure Components EUD 2018086 00 Rev 3...
Страница 50: ...50 14 May 2021 SmartScanNG User s Guide for Wayside Enclosure Components EUD 2018086 00 Rev 3...
Страница 56: ...56 14 May 2021 SmartScanNG User s Guide for Wayside Enclosure Components EUD 2018086 00 Rev 3...
Страница 68: ...68 14 May 2021 SmartScanNG User s Guide for Wayside Enclosure Components EUD 2018086 00 Rev 3...
Страница 94: ...94 14 May 2021 SmartScanNG User s Guide for Wayside Enclosure Components EUD 2018086 00 Rev 3...