Standard Pump SP-800DD Скачать руководство пользователя страница 27

27

Standard Pump Operating Instructions and Parts Manual (OIPMS0611)

STANDARD PUMP

1540 University Drive, Auburn, Georgia 30011 USA

 TOLL FREE 1-866-558-8611 • Phone 770–307–1003 • Fax 770–307–1009

e-mail: info@standardpump .com

www .standardpump .com

WARRANTY

 

 

Declaration of Conformity 

When this unit is used as a stand alone unit it complies with:

 

 

Machinery Directive 98/37/EC EN60204,

 

 

EN60335-2-41, EN60335-1, Low Voltage Directive 73/23/Eec 

 

 

EN61010-1, EMC Directive 89/336/Eec EN55014, EN 550104,

 

 

EN50081-1, EN50082-1

 

Declaration of Incorporation  

When this pump unit is to be installed into machine

 

 

or is to be assembled with other machines for

 

 

installations, it must not be put into service until

 

 

the relevant machinery has been declared in

 

 

conformity with Machine Directive 98/37/EC

 

 

EN60204, EN60335-2-41, EN60335-1 .

Responsible person: Donald M. Murphy, President, Standard Pump, Inc.

1540 University Drive,  Auburn, Georgia 30011

Ph: 001-770-307-1003 Fax: 001-770-307-1009

e-mail: info@standardpump .com

www .standardpump .com

Three year limited warranty

Standard Pump, Inc. warrants, subject to the conditions below, through either Standard Pump, Inc., it’s subsidiaries, 
or its authorized distributors, to repair or replace free of charge, including labor, any part of this equipment which 
fails within 

three years

 of delivery of the product to the end user. Such failure must have occurred because of defect 

in material or workmanship and not as a result of operation of the equipment other than in accordance with the 
instructions given in this material. Specific exceptions include:
  •  Consumable items such as motor brushes, bearings, couplings and impellers. (Motor brushes typically have a life 
    span of approximately 700 hours. This will vary with the manner in which the motor is used)
Conditions of exceptions include:
  •  Equipment must be returned by prepaid carriage to Standard Pump, Inc., its subsidiary or authorized distributor.
  •  All repairs, modifications must have been made by or with express written permission by Standard Pump, Inc.,  
    it’s subsidiary or authorized distributor.
  •  Equipment which have been abused, misused, or subject to malicious or accidental damage or electrical  

 

    surge are excluded.
Warranties purporting to be on behalf of Standard Pump, Inc. made by any person, including representatives of 
Standard Pump, Inc, its subsidiaries, or its distributors, which do not fall within the terms of this warranty shall not 
be binding upon Standard Pump, Inc. unless expressly approved in writing by a Director or Manager of Standard 
Pump, Inc. Information for returning pumps Equipment which has been contaminated with, or exposed to, bodily 
fluids, toxic chemicals or any other substance hazardous to health must be decontaminated before it is returned to 
Standard Pump, Inc, or its distributor. A returned goods authorization number (RGA #) issued by Standard Pump, Inc., 
its subsidiary or authorized distributor, must be included with the returned equipment. The RGA # is required if the 
equipment has been used. If the equipment has been used, the fluids that have been in contact with the pump and 
the cleaning procedure must be specified along with a statement that the equipment has been decontaminated.

Declarations

Содержание SP-800DD

Страница 1: ...100 SP 8200 Series 2 SP 8800 SP 8900 Series 6 SP 800SR Series 10 SP 800DD Series 11 Ultra Mass 8500 Series 16 Ultra Mag 8300 Series 18 Flow Meter Pump Systems 8320 Series 20 Motors 22 Hazardous Duty E...

Страница 2: ...liarize yourself with the pump s operation flow rate discharge pressure and motor speed 9 Before starting the pump confirm the discharge hose is securely fastened to the receiving vessel in order to p...

Страница 3: ...00 16 psi 1 1 bar SP 8200 32 psi 2 2 bar It is recommended to use a hose that is rated 4 x the pump discharge pressure Ex 32 x 4 128 psi 9 bar 5 Turn the motor to the ON position 6 After use clean the...

Страница 4: ...9 Insert screwdriver through bearing unit P N 1038 see Figure 8 When replacing the drive shaft in the bearing unit P N 1038 during reassembly make sure the drive shaft is inserted through the spacer i...

Страница 5: ...TFE 39 1000 mm 47 1200 mm Connection Flange SS316 O Ring Buna Tri Clamp SS316 Hose Barb SS316 1 25 mm Inner Outer Tube Assembly SS316 39 1000 mm 47 1200 mm O Ring Buna 2 per set Pump Housing SS316 w P...

Страница 6: ...ar It is recommended to use a hose that is rated 4 x the pump discharge pressure Ex 32 x 4 128 psi 9 bar 5 Turn the motor to the ON position 6 After use clean the pump and store vertically Disassembly...

Страница 7: ...shafts remove the impeller P N 8827 or P N 8927 see Figure 3 5 Remove O ring P N 8830 from drive shaft P N 8806 or 8807 located behind impeller P N 8827 or P N 8927 see Figure 4 6 Remove the Pump Hou...

Страница 8: ...1 Remove guide sleeve P N 8811 from drive shaft P N 8806 or P N 8807 see Figure 9 12 Secure drive shaft P N 8806 or P N 8807 with grip locks Remove coupling P N 1004 bearings P N 1038 2 bearing spacer...

Страница 9: ...FE 39 1000 mm 47 1200 mm Inner Tube Assembly SS316 39 1000 mm 47 1200 mm O Ring Buna 2 Per Set O Ring Buna Tri Clamp SS316 Hose Barb SS316 1 00 25 mm Outer Tube Assembly SS316 39 1000 mm 47 1200 mm Pu...

Страница 10: ...ith a suitable hose clamp that exceeds the pump discharge pressure 4 Make sure the speed control knob on the motor is turned to the MIN position completely counterclockwise 5 Turn the motor switch to...

Страница 11: ...turns in a clockwise direction Use the pump arrow to verify proper direction If the pump rotates counterclockwise the internal components will disassemble Do not use these pumps for the transfer of f...

Страница 12: ...7 x 4 348 psi 24 3 bar Maintenance DISASSEMBLY CLEANING PROCEDURES SP 800SR SP 800DD 1 Remove motor from pump tube For models SP 800SR loosen Hex Nut in clockwise rotation see Figure 3 For models SP 8...

Страница 13: ...shaft onto bearing housing shaft see Figure 9 6 Thread rotor onto drive shaft see Figure 8 7 Thread stator can onto pump body see Figure 7 8 Apply a suitable lubricant on rotor 9 Once Bearing Housing...

Страница 14: ...Sizes SP 1851 39 801 Pump Sizes SP 751 39 SP 752 39 SP 1851 47 802 Pump Sizes SP 751 47 SP 752 47 803 12 Stator Buna SS316 Tube Size 751 816 Size 752 817 Size 1851 818 PTFE Stator Insert Only Size 75...

Страница 15: ...Sizes SP 751 39 SP 752 39 SP 1851 47 802 Pump Sizes SP 751 47 SP 752 47 803 11 Stator Buna SS316 Tube Size 751 816 Size 752 817 Size 1851 818 PTFE Stator Insert Only Size 751 822 Size 752 823 Size 185...

Страница 16: ...ry or death Operation Ultra Mass Series 1 Please refer to the Operation SP 800SR Series portion of these operating instructions on page 10 for the pump and motor portion of this system 2 For informati...

Страница 17: ...e 1851 710 Size 752 709 10 Gasket PTFE 731 11 Outer Tube Assembly SS316 Pump Size SP 1851 39 801 Pump Size SP 752 39 802 12 Stator PTFE Insert Only Size 1851 824 Size 752 823 13 Stator Tube SS316 Size...

Страница 18: ...ration Ultra Mag Series 1 Please refer to the Operation SP 800SR series portion of these operating instructions on page 10 for the pump and motor portion of this system 2 For information regarding the...

Страница 19: ...ize 1851 710 Size 752 709 10 Gasket PTFE 731 11 Outer Tube Assembly SS316 Pump Size SP 1851 39 801 Pump Size SP 752 39 802 12 Stator PTFE Insert Only Size 1851 824 Size 752 823 13 Stator Tube SS316 Si...

Страница 20: ...or death Operation 1 Please refer to the Operation SP 800SR Series portion of these operating instructions on page 10 for the pump and motor portion of this system 2 For information regarding the cal...

Страница 21: ...PTFE 735 8 Drive Shaft SS316 705 9 Rotor SS316 710 10 Gasket PTFE 731 11 Outer Tube Assembly SS316 801 12 Stator PTFE Insert Only 824 13 Stator Tube SS316 876 14 Stator Tube for Bagliners SS316 876BL...

Страница 22: ...t Armature 110 120V 220 240V Stator 110 120V 220 240V Guide disc Rod connector Pressure spring Brush holder Carbon brush 110 120V 220 240V Motor housing plastic Star washer Fan Overload switch 8 5 amp...

Страница 23: ...plug 110 120V 220 240V Hexagon nut Rod connector Brush holder Carbon brush 110 120V 220 240V Star washer Overload switch 8 5 amp 110 120V 5 amp 220 240V low voltage release EMI Filter Repair kit 110 1...

Страница 24: ...nd 10 A1 adapter 1 2 3 4 5 6 7 8 9 10 11 12 13 14 PART NUMBER SAF350 SAC229 SAC228A SAG549 SAC617 SAC527 SAE899 SAC616 SAC190A SAE893 SD324A SAE896 SK285 9007 DESCRIPTION ITEM NUMBER PART NUMBER DESCR...

Страница 25: ...ive Body gasket Body Key Rotor assembly Push pin Vane spring Vane End plate dead Bearing dead end End cap gasket End cap dead end Muffler assembly Felt 1 1 1 1 4 1 2 1 1 1 2 4 4 1 1 1 1 1 1 AC998 AK42...

Страница 26: ...g a cast iron or aluminum case or the steel shaft of the air motor Note that electric motor enclosures for both class I and II hazardous locations can be made of iron steel copper bronze or aluminum U...

Страница 27: ...the instructions given in this material Specific exceptions include Consumable items such as motor brushes bearings couplings and impellers Motor brushes typically have a life span of approximately 70...

Страница 28: ...h_______________________ Executive Director 3 A Sanitary Standards Inc The issuance of this authorization for the use of the 3 A Symbol is based upon the volun tary certification by the applicant for...

Отзывы: