11
Standard Pump Operating Instructions and Parts Manual (OIPMS0611)
The SP-800DD Series Pump is positive
displacement pumps and should never be
operated against shut-off elements such as nozzles, valves, etc.
Failure to comply may result in excessive pressure build
resulting in serious injury and pump damage.
The SP-800DD Series Pump should not be run
dry. Running the pump dry will result in
serious damage to the mechanical seal and stator of the pump.
1. Remove the pump and motor from packaging.
2 . Inspect all contents for damages .
3. Couple the motor to the pump. Bolt electric or pneumatic
motor to the pump using the hardware provided by the
manufacturer (see figure 3) .
4. It is recommended to thoroughly clean and sanitize
SP-800DD series pumps before operation .
5 . Closed top drum or cover is recommended to prevent
possible contamination .
6 . Motor
a) Electric – make sure motor and plug are wired to proper
voltage and direction . Use wiring diagram on nameplate .
b) Air – for optimum performance make sure proper size air
lines are installed .
When using an SP-A4FP, SP-A6FP or SP-A8FP
motor, Standard Pump recommends the use
of a Fliter Lubricator Regulator (FLR) in order to ensure a
moisture free supply of air to the motor.
Do not operate the SP-800DD-1851 series
pump on viscosities greater than 10,000 cps
(mPAS). Do not operate the SP-800DD-751 or SP-800DD-752
series pumps on viscosities greater than 100,000 cps (mPAS).
Failure to comply will result in premature pump failure.
When using an SP-800DD pump in
conjunction with an air motor (SP-A4FP,
SP-A6FP or SP-A8FP), make sure the air line is connected to the
air inlet hole on the left side of the motor as you face the
motor. This will insure that the motor turns in a clockwise
direction. Use the pump arrow to verify proper direction. If
the pump rotates counterclockwise, the internal components
will disassemble.
Do not use these pumps for the transfer
of flammable or combustible products or
in an environment where flammable or combustible fumes are
present. unless used in conjunction with Explosion Proof or Air
motor. Please consult the factory or authorized distributor with
any questions regarding installation (see page 26).
Model
Air Connection
Consumption
SP-A4FP
.25" (6,33 mm)
80 CFM @ 100 psi
37 L/Sec @ 7 bar
SP-A6FP
.5" (12,7 mm)
130 CFM @ 100 psi
65 L/Sec @ 7 bar
SP-A8FP
.5" (12,7 mm)
170 CFM @ 100 psi
80 L/Sec @ 7 bar
Note:
Recommend plumbing discharge air away from drum or
tank to prevent possible contamination .
SP-800DD SERIES
Specifications
Models SP-800DD
Maximum Liquid Temperature
. . . . . . . . . . . . . Teflon Stator 300º F (148º C)
Food Grade Buna Stator 185º F (85º C)
Pump Type . . . . . . . . . . . . . . . . . . . . . . . Progressive Cavity (Positive Displacement)
Pump Speed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
900 RPM
Max. Flow Rate
. . . . . . . .751 & 752 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7 GPM (27 LPM)
1851 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 GPM (45 LPM)
Max. Discharge
Pressure . . . . . . . . . . . . . . . . . . . .751 & 1851 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .87 psi (6 bar)
752 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .174 psi (12 bar)
Immersion Length
. . . . . . . . . . . . . . . 27"
(700 mm), 39
" (1000 mm) (Tanks) &
47" (1200 mm) (Drums)
Wetted Materials . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SS 316, Teflon or White Buna
Discharge Port
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 .5"
(38 mm) Hose Barb Tri-Clamp
(Optional 1 .25"
(32 mm) Hose Barb)
Max. Viscosity
. . . . . . . . . .751 & 752 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100,000 cps (mPAS)
1851 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10,000 cps (mPAS)
Max. Solid Size
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25" (6 mm)
Motors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SP-500 Series, SP-A4FP, SP-A6FP, SPA8FP
Notes
1 . Pump stator elastomer (Teflon & Buna) may vary performance .
2. Performance is based on using a 900 RPM motor. Reducing motor
speed will decrease pump performance . Do not increase motor
speed above 900 RPM.
3. Performance will vary depending on whether the product being
pumped is newtonian (viscosity remains constant regardless of
shear) or non-newtonian (viscosity does not remain constant with
shearing).
4. Flow rates based on water. As viscosity increases, the flow rate will
decrease .
Figure 3
Air Exhaust
Air Line