16
Standard Pump Operating Instructions and Parts Manual (OIPMS0611)
The Ultra Mass Batch Control System is a
positive displacement pump system and
should never be operated against shut-off elements such as
nozzles, valves, etc. Failure to comply may result in excessive
pressure build resulting in serious injury and pump damage.
The Ultra Mass Batch Control System should
not be run dry. Running the pump dry will
result in serious damage to the mechanical seal and stator of
the pump.
Assembly
1. Remove the pump, motor, and meter from packaging.
2 . Inspect all contents for damages .
3. Couple the electric motor to the pump using the hex nut.
4. Attach the Ultra Mass meter to the pump discharge using
the supplied tri-clamp fitting.
5. Attach the check valve (p/n:384510V) to the Ultra Mass
meter using the supplied tri-clamp fitting.
6. Attach the hose barb to the check valve using the supplied
tri-clamp fitting .
7. Pump clean water in order to familiarize yourself with the
system operation .
8. It is recommended to thoroughly clean and sanitize the
Ultra Mass Batch Control System before use.
9. Use closed top drum or cover to prevent possible
contamination .
Do not use the Ultra Mass Batch Control
System for the transfer of flammable or
combustible products or in an environment where flammable
or combustible fumes are present. Failure to comply may
result in serious injury or death.
Operation – Ultra Mass Series
1. Please refer to the Operation – SP-800SR Series portion of
these operating instructions on page 10 for the pump and
motor portion of this system.
2. For information regarding the calibration and operation of
the Ultra Mass Meter, please refer to the factory operating
instructions included in this package.
Maintenance
Please refer to page 12 of these operating instructions for
information on disassembly, cleaning, and maintenance of this
system .
Note:
Motor spare parts (see page 23) Pump spare parts (see page 17)
Maintenance (see page 12)
ULTRA MASS SERIES
Notes
1. Performance will vary depending on whether the product being pumped is Newtonian
(viscosity remains constant regardless of shear) or non-Newtonian (viscosity does not remain
constant with shearing).
2. Flow rates based on water. As viscosity increases, the flow rate will decrease.
Specifications
Models 8500, 8500BL, 8501, 8501BL, 8513, 8513BL, 8514, 8514BL
Maximum Liquid Temperature
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .185º F (85º C)
Pump Type . . . . . . . . . . . . . . . . . . . . . . . . . .Progressive Cavity (Positive Displacement)
Pump Speed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
900 RPM
Metering Principle . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Coriolis Mass Flow Technology
Max. Flow Rate
. . . . . . . . . . . . 8500, 8500BL, 8501, 8501BL . . . . . . 8 GPM (30,2 LPM)
8513, 8513BL, 8514, 8514BL . . . . . 3 GPM (11,3 LPM)
Max. Discharge Pressure
. . . . . 8500, 8500BL, 8501, 8501BL . . . . . . . . . . 43 psi (3 bar)
8513, 8513BL, 8514, 8514BL . . . . . . . . . . 87 psi (6 bar)
Immersion Length
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
39
" (1000 mm)
Wetted Materials . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SS 316, Teflon
Discharge Port
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 .5"
(38 mm) Hose Barb Tri-Clamp
(Optional 1 .25"
(32 mm) Hose Barb)
Max. Viscosity
. . . . . . . . . . . . . 8500, 8500BL, 8501, 8501BL . . . . . .10,000 cps (mPAS)
8513, 8513BL, 8514, 8514BL . . . . . .25,000 cps (mPAS)
Max. Solid Size
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25" (6 mm)
Motor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . SP-ENC Series