Temperature Display
To change the displayed zone press either the
▲ or ▼ keys. The zone number icons will
change to show which zone temperature is being
displayed.
This section only applies to multi
-
zone (2 or 3 zones) kilns. A single zone
kiln will always show the temperature of zone 1 only.
For a single zone kiln the zone icons are not
used and the temperature of zone 1 is always
displayed.
For multi
-
zone kilns the temperature of each
zone can be displayed. Zone 1 is displayed by
default when the ST325 is powered on.
Control Relay Configuration
While displaying a ramp rate an event output can be
switched on or off by holding in the
function
key then
pressing either the 1 key or the 2 key. The event
output will be ON when the event icon is on.
The ST535C has 2 control relay outputs.
Control relay 1 can be configured as an event output, a damper control output or a fan
control output.
Control relay 2 can be configured as an event output only.
See the Installation section for details about configuring the control relays.
While displaying a soak period the event output can
be switched on or off by holding in the
function
key
then pressing either the 1 key. The event output
will be ON when the event icon is on.
Control Relays
Event Outputs
The control relays when configured as event outputs can be programmed to change
state at the start of a ramp and also at the start of a soak period. Thus both ramp and
soak events are possible. The event output is ON (relay contacts are closed) when
the relevant event icon is lit. Prior to running a program both event outputs are OFF
(relay contacts are open). The status of the event outputs is stored within the firing
program.
1020oC
1020oC
1018oC
150oC/HR
00:15