Page
ST535C Handbook
8
When not firing there are no indicators lit on
the mimic panel, the run indicator is off and
the display shows the current kiln
temperature.
Altering a program
The controller settings can be reviewed by pressing the ► key.
The first push of the ► key flashes the
program number display. The required firing
program can now be selected with the ▲ & ▼
keys.
Note: holding down the ▲ or ▼ keys causes rapid change of the displayed value.
The next push of the ► key displays the ramp
rate in the range END, 0.1
-
9.9°/HR, 10
-
999°/HR
or FULL. This can be altered with the ▲ & ▼
keys. The heating ramp or the cooling ramp
indicator on the mimic panel will flash. END marks the end of the program. FULL
heats or cools as fast as possible.
The next push of the ► key displays the soak
temperature. This can be altered with the ▲
& ▼ keys. The soak temperature indicator
on the mimic panel will flash.
The next push of the ► key displays the soak
period in hours:minutes. This can be altered
in the range 00:00 to 99:59 with the ▲ & ▼
keys. The soak period indicator on the mimic
panel will flash.
The next push of the ► key increments the segment number digit and
firing data for the next segment can be entered.
Program data entry is terminated if END is
selected for a ramp rate with the ▼ key. Pro-
gram data entry is also automatically terminat-
ed if the maximum number of segments have
been entered.
Note 2: to exit programming without cycling through all of the above steps wait 20 seconds without pressing any
keys
-
the ST535C will revert to the idle display. Alternatively press the
►
key to exit programming and to begin
firing immediately.
Note 3: the ◄ key can be used to reverse through the programming steps to correct errors or to exit programming
mode.
Note 1: available ramp rate displays are: END, 0.1 … 999 & FULL. If END is shown but another segment is
required then push the ▲ key to obtain the required ramp rate (in the range 0.1°/hr to 999°/hr). If maximum
heating/cooling is required then push the ▲ key until FULL is displayed. To mark the end of the program push
the▼ key until END is displayed.
20oC
PROG: 1
150oC/HR
600oC
00:15
END
Содержание ST535C
Страница 34: ...Page ST535C Handbook 34 Notes ...
Страница 35: ...ST535C Handbook Page 35 Notes ...