The ST535C is fitted with a 3m connecting lead and plug. The plug will be a
Han12Q, Han15d, CPC14 or CPC19. For kilns requiring either 1 or 2 event
outputs then either the Han12Q, Han15DX or CPC19 connector is used.
It is important to check the wiring of the kiln connector for
compatibility prior to connecting the ST535C
-
to prevent possible
damage either to the kiln or the controller!
4
12
8
3
7
11
14
1
CPC14 plug
View on pins
7
6
2
1
5
3
4
8
9
10
11
12
Han12Q plug
View on pins
Connecting Leads
Han15DX plug
View on pins
1
2
3
4
5
A
B
C
Zone 1 is the main control zone and it is normal to allocate this zone to the
bottom of a multi
-
zone kiln. Zone 2 is a slave zone and should be allocated
to the middle zone of a 3
-
zone kiln or the top zone of a 2
-
zone kiln. Zone 3
is also a slave zone and is allocated to the top zone of a 3
-
zone kiln.
Zone Allocation
1
3
4
7
8
12
13
16
17
19
CPC19 plug
View on pins