ST535C Handbook
Page
27
Mounting Location
Mount the instrument on a suitable vertical surface which will not get hot.
Choose a position where the instrument is not exposed to direct heat from
the kiln
-
especially when the kiln door or lid is open.
Mounting
Wall Mounting Bracket
This is a ‘holster’ style ABS moulded
bracket which can be attached with
2 screws. The bracket mounting
holes are spaced 100mm. The
instrument can be removed from this
bracket for in
-
hand programming if
required. Spare wall brackets are
available from Stafford Instruments
Ltd.
-
our part number: X00210.
The coil of each kiln contactor
should be suppressed
with an RC
suppressor. RC suppressors must be connected directly across the coil
terminals on each contactor. Suitable proprietary RC suppressors are often
available from contactor manufacturers as add
-
on blocks.
A suitable RC suppressor with insulated wire leads (fly leads) is the Okaya
Electric XEB1201B. These are available from Stafford Instruments Ltd.
-
our
part number: X00104.
Contactor Coil Suppression