To enter the damper temperature configuration menu press the ► key and
the key down together while the controller is not running a program (firing
indicator not lit).
Note: in the sequence below if no key presses are detected within 30
seconds the ST535C will exit the menu and damper temperature chang-
es will not be saved.
The damper close temperature prompt is
shown. Release the
&
keys.
Press the
key.
The damper close temperature is now
shown. Adjust with the &
keys (hold
down for acceleration).
Press the
key.
The damper open temperature prompt is
now shown.
Press the
key.
The damper open temperature is now
shown. Adjust with the &
keys (hold
down for acceleration)
Press the
key.
The instrument will now reset and the new damper control temperatures will
be stored.
Note: in the sequence above it is important that the
key is pressed a
total of 4 times else changes will not be saved.
Damper Output
Damper Operation
Prior to firing the damper will be open. During firing, when the kiln reaches
the damper close temperature, the damper will close. The event indicator 1
will be on.
At the end of the firing and when the kiln has cooled naturally to the damper
open temperature, the damper will open. The event indicator 1 will be off.
DAMPER:C
150oC
DAMPER:O
300oC