background image

NOTICE:

Whenever the motor housing is being removed for

service, remove oil and replace it with new oil at reassembly.
Use only oil listed in parts list in this manual. When filling
with new oil, DO NOT overfill. Allow about 7/8" (22mm) air
space from top of boss in housing for expansion of oil when
the pump is operating.

Pump Disassembly 

(The SP5 System with the SC550120T Pump only)

Impeller and Seal Replacement

A. Impeller removal

(See the pump disassembly drawing):

1.

Remove the oil fill plug and turn the pump upside
down to drain oil.

2.

Remove the capscrews holding the upper motor
housing to the lower motor housing; lift off the upper
motor housing and remove the motor lead wires from
the connector to detach upper housing from assem-
bly. The lead wires are fitted with quick connect ter-
minals for this purpose.

3.

Remove the capscrews holding the lower motor
housing to the volute; lift off the lower motor housing.

4.

Hold the rotor shaft assembly and unscrew the
impeller by turning it counter-clockwise. Remove
impeller and clean it.

If no more service is needed, reverse instructions
above to reassemble the pump. Reattach the motor
lead wires as shown in Figure 2, fill with clean
dielectric oil (Part No. U197-8A), check the oil level
and replace fill plug. Oil should cover the motor wind-
ings.

B. Shaft seal replacement:

1.

Follow the instructions to remove the impeller, above.

2.

Remove the stator capscrews and the spacers (if
applicable). Lift off the stator.

3.

Remove the seal’s ceramic seat from the shaft and tap
the body of the seal out of the lower motor housing.

4.

Clean the seal cavity thoroughly before installing the
new seal.

NOTICE:

Make sure that the seal faces

are clean; do not scratch or damage the new seal
face during seal replacement. Apply Permatex #2 or
an equivalent sparingly to the outside edge of seal
body before installing the seal in the lower motor
housing.

5.

Press the new seal body into position in the lower
housing cavity.

6.

Press the ceramic seat onto the motor shaft. The
impeller will pull it into position.

7.

Reassemble the stator and tighten the stator cap-
screws.

Risk of electrical shock.

Discharge

capacitor before handling it. Electrical shock can
burn or kill.

8.

Reassemble the impeller and the pump (reverse
instructions 1 through 4 above).

9.

Reattach the motor lead wires as shown in Figure 2.

10. Fill with clean dielectric oil (Part No. U197-8A), check

the oil level and replace the oil fill plug.

The sump basin and cover, pump, and piping should be pro-
tected from freezing temperatures. If there is any danger of
freezing temperatures, the unit should be drained. Consult
your pump manual for instructions on how to drain the pump
to protect it from freezing.

4

Short Divider

Either Black Wire

Either Black Wire

Green Wire

View

 A-A

(connected between
the two tallest
dividers)

409 0893

Figure 2

 410 0893

Oil Fill
Plug

Housing
Capscrew

Rotor/Stator
Assembly

Stator
Capscrew

Lower 
Motor
Housing

Volute

Shaft Seal,
Stationary 
Head Ass’y

Shaft Seal,
Rotating 
Mating Ring

O-Ring

Insulating 
Disk

Blk

Blk

Grn

Impeller 

Power Cord

Pump Disassembly

Содержание SP440120T

Страница 1: ...ee instructions under Service 7 Vent sewage or septic tank according to local codes 8 Do not install the basin or pump in any location classi fied as hazardous by the United States National Electrical...

Страница 2: ...wire pump to its own individual branch circuit with no other outlets or equipment in the circuit Size fuses or cir cuit breakers according to the Motor Switch and Cord Specifications chart Risk of el...

Страница 3: ...en the motor cools down the overload protector will automati cally reset and start the motor If the overload trips frequently check for the cause It could be a stuck impeller wrong low voltage or an e...

Страница 4: ...ble Lift off the stator 3 Remove the seal s ceramic seat from the shaft and tap the body of the seal out of the lower motor housing 4 Clean the seal cavity thoroughly before installing the new seal NO...

Страница 5: ...eller 1 PW5 11P 14 Volute 1 PW1 13 15 Automatic Float Switch 1 PS217 64 Switch Cord Clamp 1 CC0030 13 8 32 x 1 2 Capscrew 1 U30 539SS Dielectric Oil 1 U197 8A Not Illustrated REPAIR PARTS PUMP Key Par...

Страница 6: ...1 PW73 48 2B Sewage Basin Cover 1 PW73 60 3 Gasket Tape Cover 1 4 Sewage Basin 1 PW73 46 PW73 46 5 Inlet Hub Snap In 1 PW73 47 PW73 47 6 Discharge Pipe 1 U78 996P U78 997P 7A Sewage Pump 1 SC550120T 7...

Страница 7: ...ged 5 Check for blockage in pump inlet impeller check valve or discharge pipe 6 Disconnect the pump from the power source for a minimum of 30 minutes to allow the motor to cool and to protect yourself...

Страница 8: ...extra quick trip overload relays of recommended size are not used our warranty is void Buyer s only remedy and Sta Rite Industries only duty is to repair or replace defective products at Sta Rite Ind...

Страница 9: ...rvicio para la puesta a punto 7 Ventile el tanque s ptico o de aguas residuales conforme con los c digos locales 8 No instale el dep sito ni la bomba en ning n lugar clasificado como peligroso por el...

Страница 10: ...e en una toma de corriente el ctrica Es importante conectar o cablear la bomba a su propio ramal individual sin otro tomacorriente ni aparato conectado al circuito Determine el tama o de los fusibles...

Страница 11: ...ay una falla el ctrica en el motor haga que un experto en reparaciones lo revise La bomba tiene lubricaci n permanente No requiere aceite ni grasa MANTENIMIENTO Tensi n peligrosa Puede provocar choque...

Страница 12: ...la de la caja inferior del motor 4 Limpie bien la cavidad de la junta antes de instalar la nueva junta AVISO Aseg rese de que las caras de la junta est n limpias no raye ni da e la cara de la nueva ju...

Страница 13: ...ruptor autom tico de flotador 1 PS217 64 Abrazadera del cord n del interruptor 1 CC0030 13 Tornillo prisionero 8 32 x 1 2 1 U30 539SS Aceite diel ctrico 1 U197 8A No ilustrado PIEZAS DE REPARACI N BOM...

Страница 14: ...s 1 PW73 60 3 Cinta de empaque cubiertar 1 4 Dep sito de aguas residuales 1 PW73 46 PW73 46 5 Campana de admisi n a presi n 1 PW73 47 PW73 47 6 Tuber a de descarga 1 U78 996P U78 997P 7A Bomba de agua...

Страница 15: ...ue la admisi n de la bomba el impulsor la v lvula de retenci n o la tuber a de descarga no est n bloqueados 6 Desconecte la bomba de la fuente de corriente por un m nimo de 30 minutos para permitir qu...

Страница 16: ...paro extra r pido del tama o recomenda do nuestra garant a quedar anulada El nico recurso del comprador y la nica obligaci n de Sta Rite Industries ser n el de reparar o reemplazar los productos defec...