Electrical characteristics
ST7LITEUS2, ST7LITEUS5
12.3.3
Auxiliary voltage detector (AVD) thresholds
T
A
=
−
40 to 125°C, unless otherwise specified.
12.3.4 Internal
RC
oscillator
To improve clock stability and frequency accuracy, it is recommended to place a decoupling
capacitor, typically 100 nF, between the V
DD
and V
SS
pins as close as possible to the ST7
device.
Internal RC oscillator calibrated at 5.0 V
The ST7 internal clock can be supplied by an internal RC oscillator (selectable by option
byte).
Table 48.
Operating characteristics with AVD
(1)
1.
Refer to
Section : Monitoring the VDD main supply
.
Symbol
Parameter
Conditions
Min
(2)
2.
Not tested in production, guaranteed by characterization.
Typ
Max
Unit
V
IT+
(AVD)
1 => 0 AVDF flag toggle threshold
(V
DD
rise)
High threshold
Med. threshold
Low threshold
4.0
3.4
2.6
4.4
3.7
2.9
4.8
4.1
3.2
V
V
IT-
(AVD)
0 => 1 AVDF flag toggle threshold
(V
DD
fall)
High threshold
Med. threshold
Low threshold
3.9
3.3
2.5
4.3
3.6
2.8
4.7
4.0
3.1
V
hys
AVD voltage threshold hysteresis
V
IT+
(AVD)
-V
IT-
(AVD)
150
mV
Table 49.
Voltage drop between AVD flag set and LVD reset generation
Parameter
Min
(1)
1.
Not tested in production, guaranteed by characterization.
Max
Unit
AVD med. threshold - AVD low. threshold
800
850
950
mV
AVD high. threshold - AVD low threshold
1400
1450
1550
AVD high. threshold - AVD med. threshold
600
650
750
AVD low threshold - LVD low threshold
100
200
250
AVD med. threshold - LVD low threshold
950
1050
1150
AVD med. threshold - LVD med. threshold
250
300
400
AVD high. threshold - LVD low threshold
1600
1700
1800
AVD high. threshold - LVD med. threshold
900
1000
1050