DocID13284 Rev 2
365/564
UM0404
XBUS pulse width modulation module
This type of comparison allows a flexible control of the PWM signal. For the register
locations refer to
XPWM control register XPWMCON0
Register XPWMCON0 controls the function of the timers of the four XPWM channels and
the channel specific interrupts. Having the control bit organized in functional groups allows
to start or to stop all the four XPWM timers simultaneously with one bit-field instruction.
Note:
This register is not bit-addressable; the bit-addressability is available via specific ‘set’ and
‘Clear’ write-only registers XPWMCON0SET and XPWMCON0CLR.
XPWMCON0 (EC00h)
XBUS
Reset Value: 0000h
Table 55. XPWM module channel specific register addresses
Register
Address
Reg. space
Register
Address
Reg. space
XPW0
EC30h
XBUS
XPT0
EC10h
XBUS
XPW1
EC32h
XBUS
XPT1
EC12h
XBUS
XPW2
EC34h
XBUS
XPT2
EC14h
XBUS
XPW3
EC36h
XBUS
XPT3
EC16h
XBUS
All XPWM registers are not bit-addressable.
XPP0
EC20h
XBUS
XPP1
EC22h
XBUS
XPP2
EC24h
XBUS
XPP3
EC26h
XBUS
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
PIR3
PIR2
PIR1
PIR0
PIE3
PIE2
PIE1
PIE0
PTI3
PTI2
PTI1
PTI0
PTR3
PTR2
PTR1
PTR0
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
Bit
Function
PTRx
XPWM Timer x Run Control bit
‘0’: Timer XPTx is disconnected from its input clock
‘1’: Timer XPTx is running
PTIx
XPWM Timer x Input Clock Selection
‘0’: Timer XPTx clocked with CLK
CPU
‘1’: Timer XPTx clocked with CLK
CPU
/ 64
PIEx
XPWM Channel x Interrupt Enable Flag
‘0’: Interrupt from channel x disabled
‘1’: Interrupt from channel x enabled
PIRx
XPWM Channel x Interrupt Request Flag
‘0’: No interrupt request from channel x
‘1’: Channel x interrupt pending (must be reset via software)