Waukesha Cherry-Burrell
Installation
October 2005
95-03057
Page 19
Suggested Media Piping for Gravity Refrigeration
Liquid refrigerant from the receiver is stored in a surge drum located above the Votator II. The level in the surge drum is
automatically controlled by the level system provided with the equipment. Gravity forces the refrigerant into the cooling
jacket where it comes into contact with the heat transfer tube. The warm product causes a portion of the liquid refrigerant
to change phase, causing the heat transfer tube and the product to be cooled. The cooling rate is controlled by the
refrigerant back pressure, and hot gas can be used to push the liquid refrigerant from the Votator cylinder and rapidly
warm the system.
NOTE:
Set high pressure regulating valve 5 to 10 psi higher than outlet pressure of hot gas pressure reducing valve and
lower than the relief setting.
Figure 7 - Suggested Media Piping, Gravity Refrigeration - HORIZONTAL
Содержание Waukesha Cherry-Burrell Votator II
Страница 64: ...Parts Lists Waukesha Cherry Burrell Page 64 95 03057 October 2005 Single Mechanical Seal...
Страница 66: ...Parts Lists Waukesha Cherry Burrell Page 66 95 03057 October 2005 Double Mechanical Seal...
Страница 68: ...Parts Lists Waukesha Cherry Burrell Page 68 95 03057 October 2005 Vertical Refrigeration Piping...
Страница 73: ...Waukesha Cherry Burrell Addendum October 2005 95 03057 Page73 Addendum Votator II General Assembly...
Страница 74: ...Addendum Waukesha Cherry Burrell Page 74 95 03057 October 2005 Horizontal Refrigeration Assembly...
Страница 75: ...Waukesha Cherry Burrell Addendum October 2005 95 03057 Page75 Vertical Refrigeration System...
Страница 76: ...Addendum Waukesha Cherry Burrell Page 76 95 03057 October 2005 Horizontal Frame Options...
Страница 77: ...Waukesha Cherry Burrell Addendum October 2005 95 03057 Page77 Vertical Mounting Pole Hydraulics...
Страница 78: ...Addendum Waukesha Cherry Burrell Page 78 95 03057 October 2005 Vertical Hydraulic Schematic...
Страница 83: ......