22
9.
At this point, the run function can be turned on by returning to the
‘
Operating
’
screen and selecting
‘
run
’.
10.
Flip the CH1 trigger switch on the panel door to the right.
Note:
An external trigger can be connected to the system for remote activation.
13.
The system will begin standard operation.
6.7 MANIFOLD DISASSEMBLY
WARNING:
High Voltage. Make sure that power has been disconnected to high voltage line before any
attempt at disassembly.
STEP 1
The Manifold nozzles can be removed from the end mounts so they can be left in place and the fine
-
tuned adjust-
ments remain untouched.
Use a 5/32 Allen wrench to remove the nylon screw from the top of the end mount insulator clamps.
STEP 2
The entire nozzle body can be removed at once. Elevate the side opposite of the electrode first, and then remove the
electrode side.