SPM Instrument AB
• Box 504 • SE-645 25 Strängnäs • Sweden
Technical data are subject to change without notice.
Tel +46 152 225 00 • Fax +46 152 15075 • [email protected] • www.spminstrument.com
ISO 9001:2000 certified © SPM 2017-09. 71947 B
29
Technical specifications
Vibration channel (VIB)
Measuring range:
0.5 to 49.9 mm/s RMS (0 to 1.9 inch/s RMS)
Resolution:
0.1 mm/s (0.01 inch/s)
Frequency, lower limit:
10 Hz
Frequency, upper limit:
1000 Hz
Measuring time:
programmable 1 to 15 s
Alarm limits:
2, programmable, A1 (max) and A2 (min)
Alarm delay:
0 to 600 seconds, steps of 2 s
Fault indication:
transducer line test for short and open circuit
Transducer type:
IEPE (ICP
®
) with bias 2 to 18 V DC and sensitivity 0.9 to 12.0
mV/m/s
2
, type SLD or TRV-18/19/20/21 with isolated installation
foot TRX-18/19
Shock pulse channel (SPM)
Shock pulse method:
dBm/dBc
Measuring time:
approx. 0.4 s
Measuring range:
0 to 99 dBsv
Resolution:
1 dB
Alarm limits:
2, programmable, A1 (max) and A2 (min)
Alarm delay:
0 to 600 seconds, steps of 2 s
Fault indication:
transducer line test of measuring circuit quality, every 2 min.
Transducer type:
SPM 42000
© Copyright SPM Instrument AB. ISO 9001:2000 certified. Technical data are subject to change
without notice.
This product must be disposed as electronic waste and is marked with a crossed-out wheeled bin
symbol in order to prevent it being discarded with household waste.
When once the life cycle of the product is over You can return it to Your local SPM representative
for correct treatment, or dispose it together with your other electronic waste.
Machine Guard MG4-REF11A
Содержание Machine Guard MG4-REF11A