The VERSION menu, version and setup
The VERSION menu shows the basic setup of the MG4-REF11A unit, which is permanently pro-
grammed and cannot be changed, and also a number of general settings which can be changed
with the function keys on the front panel.
To reach the menu (A), press the RIGHT key. With SET you move the cursor to one of the four
headers. Press ENT to open the first one, VERSION (B). This shows the MG4-REF11A version, the
vibration measuring ra nge and the shock pulse transducer type. On line 4 you see the version
numbers of the three processors CPU, VIB, and SPM. None of these settings can be changed. Press
ENT to exit to the VERSION menu.
The menu under SETUP (C) allows you to make changes. Use SET to go to the setting to be changed.
The UP or the DOWN key toggles between the length measuring units mm and inch. This setting
affect the vibration velocity reading (mm/s or inch/s). Set or measured values are automatically
recalculated when the unit is changed.
Contrast means display contrast, changed with UP and DOWN. You can see the change when
repeatedly pressing one of these keys.
The TLT function is toggled ON/OFF with the UP or DOWN key. TLT = OFF means that a transducer
line fault will not let the output analog current drop below 4 mA. The yellow status light will not
be shown, but if a relay is linked to the TLT fault, it will be triggered. You can check the nature of
the TLT fault by selecting the channel with SET and pressing ENT. The TLT status is shown on the
first menu.
Relay NC (normally closed) can be toggled to Relay NO (normally open). This setting affects all
relays.
Press RIGHT for
VERSION menu
Press SET for
menu selection,
ENT to open sub menu
Press UP / DOWN to change value,
SET for menu selection, ENT to exit
Press ENT to exit
Version:
Setup:
Unit mm
Contrast
TLT On
Relay NC
Version
Setup
Password On
Measuring On
REF11A
10-1000 Hz 42000
Ver
3.00 3.00
2.00
A
B
C