On the VERSION menu,
press SET to select Password,
press UP for OFF
Press UP to change letter,
RIGHT for next position,
ENT to exit
Password:
Version
Setup
Password On
Measuring On
Password
SPM
On the VERSION menu,
press SET to select Measuring,
press UP for OFF
Version
Setup
Password On
Measuring Off
Normal measuring mode:
MG4-REF11A
VIB 1.5 mm/s
SPM 40 %
Automatic exit to
measuring mode
The VERSION menu, password and stand-by
The measuring channel configuration is protected by the password ‘SPM’. While Password = ON
is shown on the VERSION menu (A), you can enter the channel programming mode and check all
settings, but you cannot make any changes (the UP/DOWN keys are locked). On the VERSION
menu, you can select PASSWORD with SET, then change to OFF with UP or DOWN. This will open
the password menu (B), with the cursor on the first of three positions marked * * *. Press and hold
down UP until the first position reads the required letter. Step to the next position with RIGHT,
use UP to set the next letter and step to the next position with RIGHT and set the last letter. You
can also use the DOWN key to change letters, and go to the previous position with LEFT. With
ENT you exit to the VERSION menu. If you have set the password, it will now be OFF, else it is
still ON and you cannot program channels. Please note: Reset the password to ON once you have
finished programming.
Measuring = OFF means that the analog and relay outputs are frozen (stand-by mode). This set-
ting is selected before disconnecting any of the VIB or SPM input channels, else disconnecting a
transducer will cause a system fault alarm.
When no keys are pressed, the unit will automatically return from the VERSION menu to the normal
measuring result display (C) after 30 seconds. You can also exit with LEFT or RIGHT. Please note
that selecting the VERSION menu or the programming mode has the same ”freezing” effect as
setting the measuring mode to off, and that normal operation is resumed as soon as you return,
intentionally or automatically, to the measuring result display.
A
B
C