![Spinergy ZX-1 Скачать руководство пользователя страница 39](http://html.mh-extra.com/html/spinergy/zx-1/zx-1_operators-manual_1347694039.webp)
Z100080
ZX-
1 Operator’s Manual
Spinergy/SMP
Page 39
Table 3: Battery LED Codes
Number of
Battery
LEDs
Displayed
Corresponding Malfunction and Possible Solution
1
Malfunction: Battery requires charging, or poor connection exists to bat-
tery.
Possible Solution: Verify cable connections to battery are secure,
undamaged and/or charge ZX-1 battery.
2
Malfunction: Left motor has poor connection.
Possible Solution: Verify cable connections to left motor are secure and
undamaged.
3
Malfunction: Left motor has short circuit to battery condition.
Possible Solution: Contact authorized Spinergy representative for repair.
4
Malfunction: Right motor has poor connection.
Possible Solution: Verify cables connections to right motor are secure
and undamaged.
5
Malfunction: Right motor has short circuit to a battery condition.
Possible Solution: Contact authorized Spinergy representative for repair.
6
Malfunction: ZX-1 will not drive.
Possible Solution: Verify charger is not still connected0 and cable is
undamaged.
7
Malfunction: Joystick fault.
Possible Solution: Verify joystick is in center position before powering
on control system.
8
Malfunction: Control system fault indicated.
Possible Solution: Verify cable connections at control system are secure
and undamaged.
9
Malfunction: Parking brakes have poor connection.
Possible Solution: Verify parking brake and motor cable connections are
secure and undamaged. Verify control system cable connections are
secure and undamaged.
10
Malfunction: Excessive voltage has been applied to control system.
Possible Solution: A poor battery connection may exist. Verify battery
cable connections are secure and undamaged.
7 + S
Malfunction: Communication fault indicated.
Possible Solution: Verify joystick cable connections are secure and
undamaged.