101501-565 Rev C
Page 55 of 58
6.6.17 Reset Faults
Description:
The host requests the firmware to clear latched faults.
Direction:
Host to supply
Syntax:
<STX><74><,><CSUM><ETX>
Response:
If an error is detected, the Power Supply responds with:
<STX>74,!,<ERROR>,<CSUM><ETX>
Please reference the Error Code section for a list of valid error codes.
If the message is accepted, the Power Supply responds with:
<STX>74,$,<CSUM><ETX>