PROCEDURE NO.: 101501-580
REV:
A
SHEET 11 OF 12
TITLE: PROC. STANDARD ST GUI INSTALLATION INSTRUCTIONS
J:\101\101501-580.doc
5
Status, Configuration and Graphing
Besides the ‘Coms’ and ‘Main Control’ tabs are four other auxiliary tabs that display additional information
and configuration options for the system. In order, these are the ‘Status’, ‘Misc Sys Info’, ‘User Configs’ and
‘Graphs’ tabs. Each one is explain in depth below
5.1 Status Tab
This tab shows a variety of status indicators including the state of the control power, local/remote mode
indicators, the Low Voltage Power Supply problem indicator and a variety of housekeeping voltages in the
Low Voltage Power Supply.
5.2 Misc Sys Info Tab
This tab indicates the model number and software version information for the power supply, as well as the
desktop GUI version currently running.