101501-565 Rev C
Page 38 of 58
6.4
COMMAND OVERVIEW
Serial Command Overview
Command Name
<CMD>
<ARG>
RANGE
Program User Configurations
9
See Desc. See Desc.
Program kV Setpoint
10
1-4 ASCII
0-4095
Program mA Setpoint
11
1-4 ASCII
0-4095
Request kV Setpoint
14
None
-
Request mA Setpoint
15
None
-
Request Misc. Analog
Monitor Readbacks
20
None
-
Request Status
22
None
-
Request Software Version
23
None
-
Request Model Number
26
None
-
Request User Configs
27
None
-
Request Unit Scaling
28
None
-
Request FPGA Version
43
None
-
Request kV monitor
60
None
-
Request mA monitor
61
None
-
Request Slave Faults
68
None
-
Reset Faults
74
None
-
Program Local/Remote Mode
99
1 ASCII
0 or 1
6.5 RESPONSE
OVERVIEW
The command responses will follow the same format as outlined above in
section 6.1. This list is comprised of Commands with complex responses
only. Commands using a simple response will use the <$> character
(ASCII 0x24) as a “Success” response or a single character error code.
These responses will be eight ASCII characters in length.
Response Name
<CMD>
Response
Request kV Setpoint
14
11 ASCII
Request mA Setpoint
15
11 ASCII
Request Misc. Analog Readbacks
20
22 – 46 ASCII
Request Status
22
38 ASCII
Request Software Version
23
23 ASCII
Request Model Number
26
8 – 22 ASCII
Request User Configs
27
10 – 18 ASCII
Request Unit Scaling
28
10 – 15 ASCII
Request FPGA Version
43
23 ASCII
Request kV monitor
60
8 – 11 ASCII
Request mA monitor
61
8 – 11 ASCII
Request Slave Faults
68
32 ASCII
Request System Voltages
69
46 ASCII