PROCEDURE NO.: 101501-580
REV:
A
SHEET 9 OF 12
TITLE: PROC. STANDARD ST GUI INSTALLATION INSTRUCTIONS
J:\101\101501-580.doc
4 Main
Operation
1.
Once
the
software
has
established
a
connection
to
the
supply,
you
can
access
the
‘Main
Control’
tab
by
selecting
it
with
the
mouse.
This
tab
is
selected
by
default
on
startup
once
the
software
has
been
configured..
2.
From
the
main
control
screen,
you
can
see
the
current
readbacks
for
KV
and
mA,
and
you
can
also
use
the
knobs
to
set
the
remote
programming
levels
for
both
KV
and
mA.
This
screen
cannot
enable
high
voltage
output;
that
can
be
only
controlled
using
the
hardware
interface.
NOTE: In order to use the remote programming knobs, the power supply
must be put in remote mode by selecting the ‘Local/Remote’ menu, and then
selecting ‘Remote’:
3.
To
control
the
power
supply,
use
the
front
panel
or
remote
hardware
interface
to
power
on
the
supply,
and
if
you
wish
to
program
the
output
using
the
software,
follow
the
above
instructions
to
put
the
supply
in
remote
mode.
Once
the
power
supply
is
creating
high