Speidel's Braumeister
Page 8 of 32
Speidel Braumeister
Actual Temp T=015°C
11 Working with the Braumeister
11.1
Choosing the language
From the start display you move to the language choice
menu by pushing (3sec) the UP ARROW key (LNG). With
the arrow keys you can choose between GERMAN,
ENGLISH, FRENCH and SPANISH. ENTER confirms the
language selected.
11.2
Notes on temperature control
Automated operation: Begin with START (1 sec). The detailed description can be found
in the following Section, "Brewing with the Braumeister".
Programming Mode:
You move to programming mode with the ENTER key (1sec).
The detailed description can also be found in the following
Section, "Brewing with the Braumeister".
Manual operation: Press
Ļ
(1sec), to go to the Braumeister's manual operation. Using
START, the heating (H) can be switched on/off. The pump (P) is
switched on/off with ENTER. The temperature can be adjusted
with the arrow keys. By simultaneously pressing
Ļ
+
Ĺ
, you return
to the Braumeister's standby mode.
Program termination/
Back:
By simultaneously pressing
Ļ
+
Ĺ
, you jump back to the start
screen from all operating modes (automated operation,
programming mode and manual operation).
Screen
ENTER
•
Change to programming
mode (1 sec)
•
Confirm the values in programming
mode
•
Acknowledge screen prompts in
automated operation
•
Pump on/off in manual operation
Heating LED (H)
Pump LED (P)
START
•
Start the automatic brewing
process (1 sec)
•
Confirmation button while
brewing
•
Heating on/off in manual
operation
ARROW UP
•
Increase time/ temp in programming
mode and in manual operation
•
Language options (3 sec)
•
Arrow up + arrow down = Stop
automated operation or return from
manual operation
ARROW DOWN
•
Reduce time/ temp in programming
mode and in manual operation
•
Change to manual operation (1sec)
•
Arrow up + arrow down = Stop automated
operation
or return from manual operation
ROTATION SPEED CONTROL
FOR PUMP
•
Hard left: minimum
pump speed
•
Hard right: maximum
pump speed
•
Optimum rotational speed for
brewing:
pressure 0.15 bar, approx.
position 10-11