Section 4: Software Commands
Page 4-24
8197 Instruction Manual
4.2.19 TEST
MODE
This command is used to read or enter
Test Mode
operation.
Test Mode
commands are used in factory testing and field troubleshooting. The unit “times
out” of
Test Mode
and returns to
Read
Mode
operation if no commands are
issued for 15 minutes. Major and Minor alarms are asserted whenever the clock
is in
Test Mode
.
To read the
Test Mode
status (ON or OFF), issue the
TM
command as shown
below:
Type:
TM <ent>
Response:
TEST MODE ON
- OR -
TEST MODE OFF
To place the clock into
Test Mode
operation, issue the
TM
command as follows:
Type:
TM ON <ent>
Response:
TIME= 14:57:54 DATE= 2000-03-24 STATUS CHANGE <TEMP= +37.5>
COOLING FAN= OFF
ALARM RELAYS: MAJOR= ON MINOR= ON
ACTIVE ALARMS: MAJOR
IN TEST MODE
- OR -
TEST MODE= ON