Section 4: Software Commands
8197 Instruction Manual
Page 4-5
4.2.3 Clear
Alarm
The
Clear Alarm
command,
CA
, resets the Major and Minor Alarm relays even
though the fault conditions are still present. If a new alarm condition arises, the
appropriate alarm relay will be reasserted. The front panel alarm lamps are not
reset by this command. The indicator alarm lamps remain on until the fault
condition is corrected.
When a
CA
command is issued the unit responds with a change in status report.
This report time stamps when the relays were reset and lists the active alarms.
To reset the alarm relays, place the unit in Set Mode and issue the
CA
command
as follows:
Type:
CA<ent>
Example Response:
TIME= 13:44:06 DATE= 2000-03-24 STATUS CHANGE <TEMP= +36.0>
COOLING FAN= OFF
ALARM RELAYS: MAJOR= OFF MINOR= OFF
ACTIVE ALARMS: MAJOR
FREQUENCY