![Spectracom 8197 Скачать руководство пользователя страница 54](http://html1.mh-extra.com/html/spectracom/8197/8197_instruction-manual_1343628054.webp)
Section 3: Operation ______________________________________________
Page 3-16
8197 Instruction Manual
PIN SIGNAL
DESCRIPTION
1
+ 64 kHz
RS-485 B Terminal
2
-64 kHz
RS-485 A Terminal
3
+18 kHz
RS-485 B Terminal
4
-18 kHz
RS-485 A Terminal
5
+ 17 2/3 Hz
RS-485 B Terminal
6
-17 2/3 Hz
RS-485 A Terminal
7
+33 1/3 Hz
RS-485 B Terminal
8
-33 1/3 Hz
RS-485 A Terminal
9 Ground
Cable
Shield
10
Major - C
Common Contact
11
Major - NO
Normally Open
12
Major - NC
Normally Closed
13 Ground
Cable
Shield
14 Ground
Cable
Shield
15 Ground
Cable
Shield
TABLE 3-6 DATA SYNC PIN ASSIGNMENTS
NOTE: Option 14, CTCSS Outputs, replaces the 33-1/3 Hz and 17-2/3 Hz
signals with the selected CTCSS outputs #1 and #2 respectively.
Option 06, 12.8 MHz outputs, changes the 64-kHz output to 50 kHz.
Refer to Section 5, Options and Accessories, for additional information on
Options 14 and 6.
The 17 2/3-Hz and 33 1/3-Hz outputs are derived from the 10-MHz GPS
disciplined oscillator and are triggered by the GPS 1PPS output. Using the 1PPS
offset command, 1PO, these outputs can be offset from 0 to 1 second in 0.1
microsecond steps. Refer to Section 4 for additional information on the 1PO
command. The leading edges of the 17 2/3-Hz and 33 1/3-Hz outputs are
synchronized within ±400 nanoseconds of the Data Clock 1PPS output.
The 64-kHz and 18-kHz Data Sync outputs are also derived from the 10 MHz
GPS disciplined oscillator but are not leading edge synchronized to the GPS
1PPS output.