Section 4: Software Commands
NetClock/GTP Instruction Manual
Page 4-5
4.3
DISPLAY ALARM LOG
The command,
DAL
, causes the clock to output the alarm history log. Each time a
change in alarm status occurs, an alarm log is created. An alarm log includes the UTC
time and date of the log, event relay status, alarm relay status and lists the conditions
causing the alarms. The alarm log can be displayed a page at a time by adding the
letter
P
to the command. At the end of each page the option to display more or quit will
be given.
Type:
DAL <ent>
- OR -
DAL P <ent>
(paged output)
An example of a paged alarm log is shown below:
TIME = 14:01:03 DATE = 2001-04-12 STATUS CHANGE
ACTIVE ALARMS: MAJOR AND MINOR
FREQUENCY
IN TEST MODE
ADJUST OSCILLATOR
TIME = 14:01:11 DATE = 2001-04-12 STATUS CHANGE
ACTIVE ALARMS: MAJOR AND MINOR
FREQUENCY
IN TEST MODE
TIME = 14:02:13 DATE = 2001-04-12 STATUS CHANGE
ACTIVE ALARMS: MAJOR
FREQUENCY
TIME = 14:03:39 DATE = 2001-04-12 STATUS CHANGE
ACTIVE ALARMS: NONE
MORE <ANY KEY> QUIT <ESC>
TIME = 14:09:50 DATE = 2001-04-12 STATUS CHANGE
ACTIVE ALARMS: MINOR
ANTENNA PROBLEM
END OF LOG
Содержание 8183A GTP
Страница 36: ...Section 3 Operation Page 3 2 NetClock GTP Instruction Manual FIGURE 3 1 NETCLOCK GTP FRONT PANEL...
Страница 39: ...Section 3 Operation NetClock GTP Instruction Manual Page 3 5 FIGURE 3 2 NETCLOCK GTP REAR PANEL...
Страница 64: ...SECTION 4 SOFTWARE COMMANDS 4 0 INTRODUCTION 4 1 4 22 RS 232 COMMAND SET...
Страница 96: ...SECTION 5 SERVICE INFORMATION 5 0 INTRODUCTION 5 1 RECEPTION TROUBLESHOOTING 5 2 TCXO ADJUSTMENT...
Страница 102: ...APPENDIX A IRIG CODE DESCRIPTION A 0 INTRODUCTION A 1 FAA IRIG B CODE...
Страница 104: ...Appendix A FAA IRIG Code Description Page A 2 NetClock GTP Instruction Manual FIGURE A 1 FAA IRIG B TIME CODE...