Section 1: General Information
NetClock/GTP Instruction Manual
Page 1-5
Time Sync:
Indicates accuracy of time data outputs. Lamp is
green when the receiver has tracked at least one
satellite within the period allotted for the Time Sync
Alarm. The lamp is red during initial operation and
when a Time Sync Alarm is asserted. A red lamp
indicates the time data output accuracy may not be
within published specifications. Time Sync Alarm
period is programmable up to 23 hours: 59 minutes:
59 seconds in one-second increments. Factory
default is two hours.
1.5.4 RS-232
Serial
Communication Ports
Signal:
Selected data format in RS-232 levels when
interrogated by the connected device. The port may
also be configured for continuous once-per-second
output.
Connector:
DB9 female, pin assignments conform to EIA/TIA-574
standard, data communication equipment (DCE).
Flow control is not supported.
Character structure:
ASCII, 1 start, 8 data, 1 stop, and no parity.
Accuracy:
Data stream on time marker within ± 100
microseconds of UTC for Formats 0, 1, 3, and 90
selected. Formats 2 and 4 are within ±1 millisecond
of UTC.
Configuration:
Baud rate and output data formats are selected using
the Serial Setup Interface. Bit rate selections are
1200, 2400, 4800 and 9600 baud. There are six data
format selections available. In addition, time zone
offset, DST rule and interrogation character can be
configured. Each RS-232 Serial Comm port is
independently configurable.
1.5.5
RS-485 Remote Output
Signal:
Selected data format in RS-485 levels, output once
per second.
Connector:
Removable 3-position terminal block (supplied).
Character Structure:
ASCII, 1 start, 8 data, 1 stop, and no parity.
Содержание 8183A GTP
Страница 36: ...Section 3 Operation Page 3 2 NetClock GTP Instruction Manual FIGURE 3 1 NETCLOCK GTP FRONT PANEL...
Страница 39: ...Section 3 Operation NetClock GTP Instruction Manual Page 3 5 FIGURE 3 2 NETCLOCK GTP REAR PANEL...
Страница 64: ...SECTION 4 SOFTWARE COMMANDS 4 0 INTRODUCTION 4 1 4 22 RS 232 COMMAND SET...
Страница 96: ...SECTION 5 SERVICE INFORMATION 5 0 INTRODUCTION 5 1 RECEPTION TROUBLESHOOTING 5 2 TCXO ADJUSTMENT...
Страница 102: ...APPENDIX A IRIG CODE DESCRIPTION A 0 INTRODUCTION A 1 FAA IRIG B CODE...
Страница 104: ...Appendix A FAA IRIG Code Description Page A 2 NetClock GTP Instruction Manual FIGURE A 1 FAA IRIG B TIME CODE...