64
Settings
Dealer Access Settings
It is highly recommended that users consult with a factory trained technician before altering any settings behind the
‘
Dealer Access Point
’.
Changing this settings without understanding the full effect of each change can void
the warranty of your system, and cause irreparable damage.
If any settings are inadvertently changed, they can be reverted back to the defaults by using the
‘
Factory
Reset
’
feature.
Purge Setup:
Adjusts the time and maximum feed pressure allowed for the Purge Mode.
CAUTION: Perma-
nent damage to the membrane can occur if this setting is adjusted. Consult the factory before making any
adjustments.
Fresh Water Flush Settings:
Allows adjustment of the fresh water flush duration and the interval between flush-
es. If the Z
-
Ion is installed, the Flush Interval should be changed to 30 days.
Conductivity Setup:
Allows for enabling or disabling conductivity sensors on the feed water and product water.
Set the threshold for the diversion valve to divert water to the tanks.
Flow Setup:
Allows the user to adjust the flow sensor settings, or disable a flow sensor circuit altogether.
DO
NOT USE THIS SETTING TO CALIBRATE THE PRODUCT FLOW.
Follow instructions on calibrating the
flow sensor in this manual.
Tank Level Monitors:
Enable and disable the Tank Level Sensors, which read the % remaining in the tank, and
the tank switches, which allow the system to turn on/off automatically.
Boost Pressure Setup:
Enable alternate Boost Pressure sensors, change the Low Vacuum Limit, or Boost Pres-
sure Setpoint.
CAUTION: Permanent damage to the pump can occur if this setting is adjusted. Consult the
factory before making any adjustments.
Low Vacuum Limit:
The minimum boost pressure required at the inlet to the pump. This setting pre
vents the pump from getting damaged by running under high vacuum. Adjusting it to a lower number in
creases the risk that the pump will suffer damage during normal operation.
Boost Pressure Setpoint:
During startup the controller turns on the boost pump and waits for the Boost
Pressure to reach the Boost Pressure Setpoint. If the boost pressure fails to reach this setpoint, then the
main pump won
’
t turn on. Reducing the Boost Pressure Setpoint may cause the system to start, then
immediately shut down due to low boost pressure.
Outlet Pressure Setup:
Set High Pressure Limit, enable alternate high pressure sensors, select pressure sensor
scaling.
CAUTION: Permanent damage to the pump can occur if this setting is adjusted. Consult the facto-
ry before making any adjustments.
Network Setup:
Enabling the Spectra Connect Wireless access turns on a Power Over Ethernet feature on the
wired connection.
ENABLING THIS FEATURE CAN CAUSE SERIOUS DAMAGE TO YOUR SHIP
’
S
NETWORK. DO NOT ENABLE THIS FEATURE WITHOUT CONSULTING A QUALIFIED TECHNI-
CIAN OR THE FACTORY.
Содержание Bimini 300
Страница 1: ......
Страница 2: ...2 ...
Страница 4: ...4 ...
Страница 6: ...6 ...
Страница 8: ...8 ...
Страница 10: ...10 Installation Notes ...
Страница 19: ...19 John Guest Super Speedfit Fittings ...
Страница 67: ...67 Wiring Schematic ...
Страница 75: ...75 HP TB VEB B HP TB VB HP TB VEB A HP TB BV HP CB CB10 HP CYL SST HP CYL R HP CYL EC HP CYL CCA Not used ...
Страница 77: ...77 Parts 1 SO HPP PR10 ...
Страница 78: ...78 Parts PL MTS 3 8X1 2B HP CYL SST HP CYL CCA SO HPP ECCB HP CYL EC HP CYL R HP CYL PT Parts ...