32
3. Check/Adjust the flush duration
Run the watermaker for 10 minutes to fill the system with seawater, confirm that the diversion
valve opens and water is diverted to the tanks.
Press the
‘
Stop
’
button. The system will automatically fresh water flush.
Allow the fresh water flush to continue to completion. At the end of the flush cycle capture
some of the flush water at the brine discharge in a clean cup. Measure the salinity of the brine
discharge and confirm that it is below 1000ppm using a calibrated hand held TDS meter.
If the flush duration needs to be increased
, seek the Spectra Connect programming instruc-
tions in this manual.
Flush Adjustments continued...
Tank Level Sensor Calibration
1. Press the Menu Button
2. Press the Calibrate Sensors Button
3. Press the Tank Level 1 button
4. Fill the fresh water tank to be monitored.
Fig. 1
Fig. 2
Fig. 3
Fig. 4
Follow the steps in Figures
1
—
4
laid out below to enter the calibration sequence for the option-
al Tank Level Sensor(s).