SPARC Enterprise M3000 Server Installation Guide • March 2012
FIGURE 3-1
UPS Connections With a Dual-Power Feed Connection
3.3.3
Connecting the Administration Console
The server is set up and statuses are displayed from the XSCF Shell through the
serial port on the XSCF unit. To connect the administration console with the serial
port, use the RS-232C cable (serial cable) supplied with the server. Also, the XSCF
Shell and the domain console (OS console) can be used with a terminal connected to
the serial port.
Note –
The XSCF board is secured on the motherboard unit (MBU) in the M3000
server. In this document, the XSCF board in the M3000 server is called the XSCF
unit.
You can use any of the following devices with a DB-9 serial port as the
administration console:
■
ASCII terminal
■
Workstation
■
Terminal server (or a patch panel connected to a terminal server)
■
Personal computer
PSU#1 PSU#0
UPS#0
UPS#1
UPC1
UPC0
AC#0
AC#1
UPS cable
CB
CB
CB: Circuit breaker