SPARC Enterprise M3000 Server Installation Guide • March 2012
2. Turn the AC power source circuit breaker to ON.
The server starts the XSCF initialization. That can take 5 minutes.
Note –
If the power supply is interrupted as a result of disconnecting the power
cord or using the circuit breaker on the power distribution panel, wait at least 30
seconds before turning on the server again.
3. Check the LEDs of the XSCF unit.
FIGURE 3-4
shows the locations of the LEDs on the rear panel of the XSCF unit.
The CHECK LED (1) of the XSCF unit is turned on almost immediately after the AC
power supply system is turned on. The READY LED (2) of the XSCF unit flashes
during XSCF initialization and stays on when the initialization has been completed.
FIGURE 3-4
LEDs on the XSCF Unit
4. Watch the administration console for error messages as the XSCF Unit powers on.
For details on troubleshooting during installation work, refer to
Appendix B
.
5. Confirm that the XSCF STANDBY LED (green) on the operator panel is lit.
6. When the login prompt appears, type
default
as the login name
.
Location Number
LED Name
1
CHECK LED
2
READY LED
login:
default
2
1