Particulate and Coalescing Filter
The particulate and coalescing filter after the air compressor is designed to capture particulate and moisture prior to
entering the rest of the system. These filters need to be replaced once per year or every 1000 hours, whichever
comes first. To do so,
1.
Make sure there is no pressure on the filter bowls. The gauge after the filter bowl will read 0 PSIG to
indicate that there is no pressure on the bowl.
2.
Unscrew the filter bowls by turning them counter clockwise.
3.
Once the filter bowls have been removed, rinse any debris out of the bowls with warm water.
4.
Dry the bowls with a clean dry cloth and replace the old O-rings with the ones provided in the kit.
5.
Using a Philips-Head screwdriver, remove the particulate element and replace.
6.
The coalescing element can be removed by turning it counter-clockwise with your hand; then replaced with
the new element in the reverse order.
7.
Once both elements have been replaced, bowls have been cleaned and O-rings replaced, the bowls can
be screwed back in to their corresponding filter housings.
Once all the filters have been replaced, press the filter reset button on the electrical panel. Put the front cover back
on the cabinet and the unit can be powered up again. Once powered up, you should hear the air compressor turn
on and the
BeerBlast™ 7/14KPH / N
2
-
GEN™ 7/14KPH will be producing nitrogen.
Содержание BEERBLAST 14KPH
Страница 3: ...BeerBlast 7 14KPH N2 GEN 7 14KPH O M South Tek Systems 3 Notes Page ...
Страница 5: ...BeerBlast 7 14KPH N2 GEN 7 14KPH O M South Tek Systems 5 Notes ...
Страница 16: ...BeerBlast 7 14KPH N2 GEN 7 14KPH O M South Tek Systems 16 ...
Страница 17: ...BeerBlast 7 14KPH N2 GEN 7 14KPH O M South Tek Systems 17 ...
Страница 19: ...BeerBlast 7 14KPH N2 GEN 7 14KPH O M South Tek Systems 19 Figure 1 100 N2 Storage Tank Setup ...
Страница 31: ...BeerBlast 7 14KPH N2 GEN 7 14KPH O M South Tek Systems 31 Last Page ...