™ 7/14KPH O&M
South-Tek Systems
13
4.3
ELECTRICAL REQUIREMENTS
The
BeerBlast™ 7/14KPH / N
2
-
GEN™ 7/14KPH requires 110–220V / 50-60 hz / 1ph connection. It has a built in
20A circuit breaker and a standard 3-prong US power cord is provided for the electrical connection. The system is
UL 508A ICP approved. Electrical schematic available upon request.
4.4
MOUNTING (
BEERBLAST™ 7KPH / N
2
-GE
N™ 7KPH)
The
BeerBlast™ 7KPH / N
2
-
GEN™ 7KPH can be mounted to a wall or placed on a floor. It is recommended that
the
BeerBlast™ 7KPH / N
2
-
GEN™ 7KPH be mounted to a weight-bearing wall that can support its weight as
specified in Specification
s (BeerBlast™ 7KPH / N2-GEN™ 7KPH). If placed on t h e floor, it should still be
fastened in place so that it cannot move due to vibration or damaged from falling over. The
BeerBlast™
7KPH / N
2
-
GEN™ 7KPH
should always be installed indoors in an environment between 40° and 85° F in the
upright position where it will not be damaged by water or moving equipment.
Leave at least 6” on the left side of
the cabinet for ventilation, but 36” is recommended for access to the control panel, tube/pipe connections, and the
front cover. There is a ¼” OD tube drain port on the bottom right of the cabinet. This can be plumbed to the nearest
site drain.
There is an optional mounting bracket kit (STS Part #: A05-TYP1-RD), that allows you to mount the system on a
standard 16
” wall stud width. Otherwise, use the mounting holes on the cabinet for mounting the BeerBlast™
7KPH / N
2
-
GEN™ 7KPH
securely and level, directly to the wall.
Optional Mounting Bracket Kit Procedures
1.
All
BeerBlast™ 7KPH / N
2
-
GEN™ 7KPH
mounting holes and optional mounting bracket holes are for
¼” screws/anchors.
2.
All brackets must be installed in orientation as shown to work correctly.
3.
Install the cabinet-mounting brackets on the
BeerBlast™ 7KPH / N
2
-
GEN™ 7KPH
first with the
bolts/lock nuts that are provided.
4.
Locate the wall-
mounting bracket. It is an 18” bracket without the rectangular cutouts and will need to
be installed on the wall at the desired height and level. The bracket has 16” center to center holes so
the unit can be mounted directly to studs. This bracket will need to be mounted per the diagram below
using appropriate for your type of wall material (wood, sheet metal, masonry, etc.…). Once the 18”
bracket has been wall mounted, this will allow the 12” bracket that is fastened to the top flange of the
cabinet a fixed anchor to hang from. See diagram as to how the angles are to be oriented on the back
of the cabinet vs the wall.
a.
Use the supplied nuts and bolts to attach the upper 12” bracket onto the top flange per the
diagram.
b.
Use the supplied carriage bolts and nuts to attach the 18” lower bracket to the bottom flange,
don’t overtighten the nuts yet. After installing the system, you may want to offset the bracket
slightly, hence the rectangular slots.
5.
Optional: if w
all studs are not 16” center to center or you have the need to reinforce mounting area, a
½” or thicker plywood is recommended to be installed prior to hanging the system. Use best general
practices to ensure that the wood and system will be secure at its full weight and remember that it will
be vibrating from compressor running.
6.
Once the mounting brackets are all in place, hang the
BeerBlast™ 7KPH / N
2
-
GEN™ 7KPH
cabinet
from the top bracket making sure it is centered.
a.
The cabinet should have at least 4” on either side for breathing/cooling purposes.
b.
Do not install near heat source or where steam or water is present. Damage to system or
bodily harm may result as well as voiding warranty.
Warning: Secure the
BeerBlast™ 7KPH / N
2
-
GEN™ 7KPH
to the wall at the top and bottom flanges. Failure to do
so could cause damage or bodily injury.
Содержание BEERBLAST 14KPH
Страница 3: ...BeerBlast 7 14KPH N2 GEN 7 14KPH O M South Tek Systems 3 Notes Page ...
Страница 5: ...BeerBlast 7 14KPH N2 GEN 7 14KPH O M South Tek Systems 5 Notes ...
Страница 16: ...BeerBlast 7 14KPH N2 GEN 7 14KPH O M South Tek Systems 16 ...
Страница 17: ...BeerBlast 7 14KPH N2 GEN 7 14KPH O M South Tek Systems 17 ...
Страница 19: ...BeerBlast 7 14KPH N2 GEN 7 14KPH O M South Tek Systems 19 Figure 1 100 N2 Storage Tank Setup ...
Страница 31: ...BeerBlast 7 14KPH N2 GEN 7 14KPH O M South Tek Systems 31 Last Page ...