2-9-2.
SWC-56 Board/EC-78 Board
Preparation
1.
Remove the bottom panel assembly. (Refer to
2.
Remove the inside panel assembly. (Refer to
“2-6-1. Inside Panel Assembly”
)
3.
Remove the outside panel assembly. (Refer to
“2-7-1. Outside Panel Assembly”
)
4.
Remove the rear panel assembly. (Refer to
)
5.
Remove the handle assembly. (Refer to
6.
Remove the SxS slot assembly. (Refer to
Procedure
1.
Disconnect the flexible board from the connector (CN103) on the SWC-56 board.
2.
Remove the two screws to detach the AU volume assembly.
P2 x 4
AU volume assembly
Flexible board
SWC-56 board
CN103
3.
Disconnect the harness from the connector (CN102) on the SWC-56 board.