![Sony PMW-300 Скачать руководство пользователя страница 95](http://html.mh-extra.com/html/sony/pmw-300/pmw-300_service-manual_1323744095.webp)
Error value
Diagnosis
1
Path: Pin A2 → pin G22
Data: 0x55550000
Starting serial output channel: Channel 4
2
Path: Pin A2 → pin G22
Data: 0xaaaa0000
Starting serial output channel: Channel 4
3
Path: Pin A3 → pin H22
Data: 0x55550000
Starting serial output channel: Channel 6
4
Path: Pin A3 → pin H22
Data: 0xaaaa0000
Starting serial output channel: Channel 6
Item5 (System controller block diagnosis)
The system controller block diagnosis tests the following contents.
ID
Diagnosis
Error value
Type1/2
Note
0x01
I
2
C communication test (RTC)
-1: Error
1, 2
The unit must have started
and a sub-microcomputer
must be connected.
0x02
I
2
C communication test (EEPROM)
-1: Error
1, 2
The unit must have started
and a sub-microcomputer
must be connected.
0x03
I
2
C communication test (power sup-
ply microcomputer)
-1: Error
1, 2
The unit must have started
and a sub-microcomputer
must be connected.
0x04
I
2
C communication test (sub-micro-
computer of the inside panel)
-1: Error
1, 2
The unit must have started
and a sub-microcomputer
must be connected.
0x05
I
2
C communication test (sub-micro-
computer of the handle)
-1: Error
1, 2
The unit must have started
and a sub-microcomputer
must be connected.
0x06
I
2
C communication test (sub-micro-
computer of the rear panel)
-1: Error
1, 2
Normal end "0" is always re-
turned because there is no ap-
plicable device in this unit.
0x07
I
2
C communication test (sub-micro-
computer of the outside panel)
-1: Error
1, 2
Normal end "0" is always re-
turned because there is no ap-
plicable device in this unit.
0x08
I
2
C communication test (sub-micro-
computer of the viewfinder)
-1: Error
1, 2
Normal end "0" is always re-
turned because there is no ap-
plicable device in this unit.
0x09
I
2
C communication test (I/O expand-
er)
-1: Error
1, 2
The unit must have started
and a sub-microcomputer
must be connected.
0x0a
Version matching test (power supply
microcomputer)
-1: Error
1, 2
The unit must have started
and a sub-microcomputer
must be connected.
0x0b
Version matching test (sub-micro-
computer of the inside panel)
-1: Error
1, 2
The unit must have started
and a sub-microcomputer
must be connected.
0x0c
Version matching test (sub-micro-
computer of the handle)
-1: Error
1, 2
The unit must have started
and a sub-microcomputer
must be connected.
Continued
PMW-300
3-11
Содержание PMW-300
Страница 1: ...SOLID STATE MEMORY CAMCORDER PMW 300 SERVICE MANUAL 1st Edition ...
Страница 4: ......
Страница 8: ......
Страница 10: ......
Страница 98: ......
Страница 106: ......
Страница 130: ......
Страница 133: ......
Страница 134: ...PMW 300 J PMW 300 UC PMW 300 CE PMW 300 E PMW 300 CN J E 9 878 486 01 Sony Corporation Printed in Japan 2013 9 08 2013 ...