2-11-3. KSW-65 Board
Preparation
1.
Remove the bottom panel assembly. (Refer to
2.
Remove the inside panel assembly. (Refer to
“2-6-1. Inside Panel Assembly”
)
3.
Remove the outside panel assembly. (Refer to
“2-7-1. Outside Panel Assembly”
)
4.
Remove the rear panel assembly. (Refer to
)
5.
Remove the handle assembly. (Refer to
6.
Remove the handle U-case assembly. (Refer to
“2-11-2. Handle U-case Assembly”
Procedure
1.
Disconnect the flexible flat cable from the connector (CN101) on the KSW-65 board.
2.
Remove the five screws and lift up the KSW-65 board.
3.
Disconnect the HN-413 board from the connector (CN400) on the KSW-65 board.
4.
Disconnect the flexible flat cable from the connector (CN100) on the KSW-65 board.
5.
Remove the JS knob from the KSW-65 board.
KSW-65 board
CN400
P2 x 4
JS knob
CN101
P2 x 4
CN100
Flexible flat cables
HN-413 board
6.
Install the removed parts by reversing the steps of removal.