– 31 –
[V.COM R]
• Make this adjustment through a visual check.
Note:
The view angle correction must be turned off.
Before this adjustment, the Contrast Adjustment must be finished.
Condition:
Input signal
Monoscope signal
Measurement point
Right LCD screen
Measuring equipment
Visual check
Adjustment page
D
Adjustment address
28
Adjustment Procedure:
(1)
Select EXT. VIDEO AUDIO mode, and picture and tone qual-
ity standard setting. (See page 22)
(2)
View angle correction OFF: Connect CN404 pin
2
(EAC OFF)
and pin
1
(GND) on the RG-46P board.
(3)
Set (or confirm) data:01 to page: 1, address: 00.
(Cancel D page protect)
(4)
On page: D, address: 28, change data with the PLAY and STOP
buttons and press the PAUSE button to write data so that hori-
zontal streaks do not wobble on the display when looking into
the right finder window.
Adjustment and Adjustment Parts: RG-46P board (see page 33)
[V.COM L]
• Make this adjustment through a visual check.
Note:
The view angle correction must be turned off.
Before this adjustment, the Contrast Adjustment must be finished.
Condition:
Input signal
Monoscope signal
Measurement point
Left LCD screen
Measuring equipment
Visual check
Adjustment page
D
Adjustment address
29
Adjustment Procedure:
(1)
Select EXT. VIDEO AUDIO mode, and picture and tone qual-
ity standard setting. (See page 22)
(2)
View angle correction ON: Connect CN404 pin
2
(EAC OFF)
and pin
1
(GND) on the RG-46P board.
(3)
Set (or confirm) data: 01 to page: 1, address: 00.
(Cancel D page protect)
(4)
On page: D, address: 29, change data with the PLAY and STOP
buttons and press the PAUSE button to write data so that hori-
zontal streaks do not wobble on the display when looking into
the left finder window.
Adjustment and Adjustment Parts: RG-46P board (see page 33)
[Color Adjustment]
Note:
The view angle correction must be turned off.
Condition:
Input signal
Color bar signal
Measurement point
RG-46P board CN404 pin
4
Measuring equipment
Oscilloscope
Adjustment page
D
Adjustment address
31
Specification value
290 ± 15 mV
Connection:
Adjustment Procedure:
(1)
Select EXT. VIDEO AUDIO mode, and picture and tone qual-
ity standard setting. (See page 22)
(2)
View angle correction OFF: Connect CN404 pin
2
(EAC OFF)
and pin
1
(GND) on the RG-46P board.
(3)
Connect an oscilloscope to the CN404 pin
4
on the RG-46P
board.
(4)
Set (or confirm) data: 01 to page: 1, address: 00.
(Cancel D page protect)
(5)
On page: D, address: 21, change data with the PLAY and STOP
buttons and press the PAUSE button to write data so that the
F
level of waveform on the oscilloscope satisfies the specifi-
cation value.
Adjustment and Adjustment Parts: RG-46P board (see page 33)
CN404 pin
4
(G OUT)
CN404 pin
1
(GND)
RG-46P Board
+
–
Oscilloscope
(DC range)
F
H
Содержание PLM-A55E
Страница 1: ...SERVICE MANUAL GLASSTRON AEP Model UK Model SPECIFICATIONS PLM A55E 9 928 101 31 ...
Страница 3: ... 3 SECTION 1 GENERAL This section is extracted from instruction manual ...
Страница 4: ... 4 ...
Страница 5: ... 5 ...
Страница 6: ... 6 ...
Страница 7: ... 7 ...
Страница 8: ... 8 ...
Страница 9: ... 9 ...
Страница 10: ... 10 ...
Страница 11: ... 11 ...
Страница 12: ... 12 ...
Страница 13: ... 13 ...
Страница 14: ... 14 ...
Страница 48: ... 64 65 66 4 11 SCHEMATIC DIAGRAM SA 52P Board See page 75 for IC Block Diagrams PLM A55E Page 57 ...