56
Continued
Main
Code
Sub
Code
ERROR/ALARM indicator
Description
Error remedy method
Refer to section
Lighting
interval
Switching off
condition
95
50F
1 second
Power
The BRIDGE (IC700
internal: BD-48 board)
detected an abnormal stop
of the fan (DC FAN (L)).
1. Eject the cartridge.
2. Startup the maintenance menu and perform [CHECK] > [DEVICE] >
[FAN MOTOR].
When the check result is “NG”, check the installation of the relevant fan
and the cable connection.
•
Improper connection (half insertion or oblique insertion)
•
Damage to connectors
•
Significant scratches or disconnection of flexible cables
•
Damage or dust/dirt at connecting parts (Unplug flexible cables.)
510
1 second
Power
No data can be read from
the EEPROM (IC709:
BD-48 board).
Acquire the drive/driver log, and then turn off and on the unit.
•
In the case no error occurs:
The problem is fixed. Use the unit as it is.
•
If the same error occurs repeatedly:
Send the acquired drive/driver log to your local Sony Sales Office/Service
Center.
-
511
1 second
Power
An EEPROM (IC709:
BD-48 board) error was
detected.
512
0.25 seconds
Power
A BPI-FLASH (IC701:
BD-48 board) data error
was detected.
1. Turn off and on the unit.
2. Upgrade the firmware again.
If this error still remains, the BD-48 board may be defective.
513
0.25 seconds
Power
No data can be written to
the BPI-FLASH (IC701:
BD-48 board) during
firmware upgrade.
Содержание PDW-U4
Страница 7: ...4 Frame Wiring 151 Revision History 152 ...
Страница 24: ...21 Hold the shaded portions Keep away a screwdriver Objective lens Actuator ...
Страница 147: ...144 Frame Assembly 2 310 309 310 309 311 311 311 311 307 306 305 302 308 304 311 306 311 303 301 311 307 ...
Страница 155: ...152 Revision History Date History Contents 2020 10 1st Edition 9 932 764 01 ...
Страница 156: ...PDW U4 SY PDW U4 CN J E 9 932 764 01 Sony Corporation Printed in Japan 2020 10 08 2020 ...