109
8. Execute the [PDWTerminal.exe] file in the [PDW-U1 Service Software] folder.
Details of the PDWTerminal window (Basic operation)
Tip
When there are instructions to press “MENU KEY” in the menu window, press the [LEFT].
If the maintenance menu does not work normally
If the maintenance menu is not displayed on the menu window, the following possible causes are
considered. Clear the possible causes and then click the [EXIT] to exit the program. Then re-execute the
[PDWTerminal.exe] file.
Symptom:
“USB DEVICE NOT READY” appears in the status area.
Possible cause:
•
This unit is not powered on.
•
No USB cable is connected.
•
An incorrect drive name is set.
•
This unit is not recognized by the PC due to a cause other than above.
Symptom:
“ABORTING” appears momentarily on the menu window and “COMMAND SEQUENCE ERROR”
appears in the error message area.
Possible cause:
A cartridge is remaining in the unit.
No.
Button Name
Description
1
SET
Executes the selected menu and items in the menu.
2
EXIT
Exits the maintenance mode.
3
UP/DOWN
Moves the cursor on the menu.
4
LEFT
Moves to one-level higher menu layer and exits a menu.
5
RIGHT
Moves to one-level lower menu layer.
Содержание PDW-U4
Страница 7: ...4 Frame Wiring 151 Revision History 152 ...
Страница 24: ...21 Hold the shaded portions Keep away a screwdriver Objective lens Actuator ...
Страница 147: ...144 Frame Assembly 2 310 309 310 309 311 311 311 311 307 306 305 302 308 304 311 306 311 303 301 311 307 ...
Страница 155: ...152 Revision History Date History Contents 2020 10 1st Edition 9 932 764 01 ...
Страница 156: ...PDW U4 SY PDW U4 CN J E 9 932 764 01 Sony Corporation Printed in Japan 2020 10 08 2020 ...