44
3-2-4. Error 5X
When a read data error is detected, one of the following error codes is displayed.
Continued
*1: For cartridges that can be read and written by this unit, refer to the Operating Instructions.
Main
Code
Sub
Code
ERROR/ALARM indicator
Description
Error remedy method
Refer to section
Lighting
interval
Switching off
condition
50
010
0.25 seconds
Disc/Power
BCA area data cannot be
read.
1. Eject the cartridge.
2. Insert another cartridge.
•
In the case no error occurs:
The ejected cartridge is likely to be faulty.
•
In the case the error occurs:
A drive fault is likely.
-
011
0.25 seconds
Disc/Power
BCA area data is invalid.
51
020
0.25 seconds
Disc/Power
PIC area data cannot be
read.
1. Eject the cartridge.
2. Insert another cartridge.
•
In the case no error occurs:
The ejected cartridge is likely to be faulty.
•
In the case the error occurs:
A drive fault is likely.
-
021
0.25 seconds
Disc/Power
PIC area data is invalid.
500
0.25 seconds
Disc/Power
An unspecified disc
*1
was
inserted.
53
500
1 second
Disc/Power
Recording to disc was
attempted with no
available spare area.
1. Eject the cartridge.
2. Insert another cartridge. Record data to the cartridge.
-
Содержание PDW-U4
Страница 7: ...4 Frame Wiring 151 Revision History 152 ...
Страница 24: ...21 Hold the shaded portions Keep away a screwdriver Objective lens Actuator ...
Страница 147: ...144 Frame Assembly 2 310 309 310 309 311 311 311 311 307 306 305 302 308 304 311 306 311 303 301 311 307 ...
Страница 155: ...152 Revision History Date History Contents 2020 10 1st Edition 9 932 764 01 ...
Страница 156: ...PDW U4 SY PDW U4 CN J E 9 932 764 01 Sony Corporation Printed in Japan 2020 10 08 2020 ...