Outputting Audio Linked to Alarm Detection — Voice alert Menu
85
Camera tampering detection:
Select this option to link
the alarm output to be triggered when the camera
detects tampering, such as direction shift or spraying.
Motion detection:
Select this option when you link the
alarm output to the motion detection function.
Click
Detection
, and the Motion detection menu is
displayed to allow you to set the motion detection
function (page 90).
Note
In the case that the synchronized preset position is
specified in
Position at alarm
in the Preset position
menu, the alarm event that happens when the camera
moves to the preset position will be invalid.
Alarm duration
Select the duration for which the alarm is output,
between 1 and 60 sec.
Effective period
This item becomes active when
Mode
is set to
Alarm
.
Set the period during which the alarm detection is
effective.
Always:
Alarm detection is always effective.
Schedule:
You can specify the period during which
alarm detection is effective.
Click
Schedule
and the menu for the effective period
is displayed. (“Setting the Schedule — Schedule
Menu” on page 88)
Timer
Controls alarm output using the timer.
Click
Schedule
and the menu for the effective period is
displayed. (“Setting the Schedule — Schedule Menu”
on page 88)
Day/Night
Controls the alarm output linked to the day/night
function.
OK/Cancel
See “Buttons common to every menu” on page 35.
Outputting Audio Linked
to Alarm Detection
— Voice alert Menu
Click
in the Administrator menu to display
the Voice alert menu. Use this menu to set the voice alert
function to output audio from the line output jack of the
camera when an alarm is detected by the sensor input or
detection functions.
You can output audio from a speaker connected to the
camera in synchronization with an alarm event triggered
by the sensor input or the detection functions.
The Voice alert menu consists of 3 tabs:
Voice alert 1
,
Voice alert 2
and
Voice alert 3
. You can configure an
individual audio file on each tab.
Note
Before using the voice alert function, you need to save
the audio file to the camera using the SNC audio upload
tool stored in the supplied CD-ROM.
For details on use of the SNC audio upload tool, see
page 112.
Voice alert 1, 2, 3 Tab
File
Displays the name of the audio file saved in the camera.
“Not uploaded” is displayed dimly if no audio file is
saved.
To delete the audio file saved in the camera, click
Delete
.
Note
Before deleting an audio file, set
Voice alert
to
Off
.
Voice alert