41
(GB)
Settings
To activate series recording, set each of the connected
HSR-X200/X200P units as follows with 4.
RECORDING CONDITIONS SET of MAIN MENU
1.
For details on menu operations, see “Menu Operations” on
page 17(GB).
<RECORDING CONDITIONS SET>
SERIES RECORDING : OFF
NORMAL RECORDING AREA
OVERWRITE : OFF
ALARM RECORDING AREA
OVERWRITE : OFF
REMAINING DISK WARNING : 1%
Set SERIES RECORDING to ON.
Set OVERWRITE to OFF for both NORMAL
RECORDING AREA and ALARM RECORDING
AREA.
For details on OVERWRITE, see “Recording Area Settings”
on page 52(GB).
Notes
• Series recording cannot be performed if timer
recording has been specified.
Be sure that the TIMER button indicator is dark on
all the connected HSR-X200/X200P units.
• If the OVERWRITE function is set to ON on any of
the connected HSR-X200/X200P units, recording
will be continued on that unit.
To start series recording
Press the
z
REC button on the first HSR-X200/
X200P.
Repeat recording
You can continue recording (overwriting) by returning
to the first unit when the recording area of the last unit
becomes full.
To achieve this repeat recording, connect the SERIES
OUT and COM terminals of the last unit to the
SERIES IN and COM terminals of the first unit.
Note
This function is valid with normal recording and alarm
recording only.
Multiplexer Connection and
Associated Settings
Connection example
Settings
Specify the type of the connected multiplexer with
2. VIDEO INPUT/PRE REVERSE of MAIN MENU 1.
For details on menu operations, see “Menu Operations” on
page 17(GB).
<VIDEO INPUT>
MULTIPLEXER : NO USE
<PRE REVERSE PLAY>
PRE REVERSE PLAY TIME : 10 MIN
SONY: Sony-made multiplexer (YS-DX516/DX516P,
etc.)
OTHERS1: Sanyo-made multiplexer
OTHERS2: Multiplexer of Dedicated Micro and
Robot
OTHERS3: Multiplexer of other manufacturers
NO USE: Not to use any multiplexer
PC CARD
MIC
AUDIO
IN
IN
OUT
OUT
LOOP OUT
IN
OUT
LOOP OUT
RS-232C
S-VIDEO
VIDEO
IN
IN
OUT
OUT
WARNING OUT
CLOCK
NON REC OUT
ALARM
RESET
FULL
ALARM
FULL
ON
RS485
TERMINATE
OFF
COM
COM
A
B
IN OUT
COM
COM
COM
COM
COM
REMOTE
RS485
SERIES
SW OUT
-
AC IN
VIDEO
OUT
ALARM
COM
+ OUT
SW OUT
+ COM
VIDEO
IN
ALARM
COM
+ IN
SW (VEXT) IN
+ C
AL
VCR IN
VCR OUT
HSR-X200/X200P
Multiplexer
to an AC outlet