6-129
HVR-S270J/S270U/S270N/S270E/S270P/S270C
4.
Switch Check (1)
Page 2
Address 81
Using method:
1) Select page: 2, address: 81.
2) By discriminating the bit value of display data, the state of switch can be discriminated.
5.
Switch Check (2)
Page 3
Address 62
Using method:
1) Select page: 3, address: 62.
2) By discriminating the bit value of display data, the state of switch can be discriminated.
6.
Switch Check (3)
Page 7
Address 48
Using method:
1) Select page: 7, address: 48.
2) By discriminating the bit value of display data, the state of switch can be discriminated.
3.
Bit Value Discrimination
Bit values must be discriminated using the display data of the ad-
justment remote commander for the following items. Us the table
below to discriminate if the bit value is “1” or “0”.
(Example) If the remote commander display is “8E”, bit value from
bit 7 to bit 4 can be discriminated from the column
A
,
and those from bit 3 to bit 0 from column
B
.
Page
Address
bit3 to bit0 discrimination
bit7 to bit4 discrimination
Display on the adjustment remote commander
Display on the
adjustment
remote
commander
0
1
2
3
4
5
6
7
8
9
A (
A
)
B (
b
)
C (
C
)
D (
d
)
E (
E
)
F (
F
)
Bit values
bit3
or
bit7
0
0
0
0
0
0
0
0
1
1
1
1
1
1
1
1
bit2
or
bit6
0
0
0
0
1
1
1
1
0
0
0
0
1
1
1
1
bit1
or
bit5
0
0
1
1
0
0
1
1
0
0
1
1
0
0
1
1
bit0
or
bit4
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
A
B
Bit
Function
When bit value = 1
When bit value = 0
0
POWER (PW-135 board S6802)
ON
OFF
1
CAMERA/VCR (PW-135 board S6801)
CAMERA
VCR
3
EJECT (EJ-040 board S9101)
ON
OFF
4
5
DISPLAY (LS-071 board S7808)
ON
OFF
Bit
Function
When bit value = 1
When bit value = 0
7
CC DOWN (Mechanism chassis)
ON (DOWN)
OFF (UP)
Bit
Function
When bit value = 1
When bit value = 0
0
TALLY (EV-018 board S9002)
OFF
ON
1
LIGHT MAN/AUTO (SH-029 board S5101)
AUTO
MAN
2
MAN
AUTO